ETD MC/MT / ETD MC/MT + PTS

Parameter

Description

Tool start trigger

  • Disabled – Disable start function. Button can now be used as a function instead of a start trigger.

  • Hold – Button must be continuously pressed down to run tool. Releasing the trigger will abort the tightening/loosening.

  • Pulse – Button must be pressed to start a tightening/loosening. Releasing the trigger will not abort the tightening/loosening.

Trigger start function

Only available if Tool start trigger is set to Disabled.

  • None – Tool start trigger will do nothing.

  • Input function – Button can be used as a digital input instead of a start trigger.

  • Toggle vacuum – Press once to activate the vacuum pump. Press again to deactivate the vacuum pump.

  • Toggle guiding light – Press once to activate the guiding light. Press again to deactivate guiding light.

Trigger start input function

Only available if Tool start function is set to Input function.
Sets a digital input function that will be activated as soon as button is pressed.

See also Digital I/O

Trigger Push-To-Start

  • Disabled – Button is disabled.

  • Hold – Button must be continuously pressed down to run tool. Releasing the trigger will abort the tightening/loosening.

  • Pulse – Button must be pressed to start a tightening/loosening. Releasing the trigger will not abort the tightening/loosening.

Config single function

  • Input function – Button can be used as a digital input.

  • Single reverse – Start trigger will activate a loosening once. Next time start trigger is pressed it will do a tightening.

  • Toggle reverse – Start trigger will only start a loosening. Pressing config button again will make the start trigger run tightenings again.

  • Toggle vacuum – Press once to activate the vacuum pump. Press again to deactivate the vacuum pump.

  • Toggle guiding light – Press once to activate the guiding light. Press again to deactivate guiding light.

  • Toggle output function – Button can be used to set an external monitored output.

  • Pulse output function – Button can be used to pulse an external monitored output.

Config single input function

Only available if Config single function is set to Input function.
Sets a digital input function that will be activated as soon as button is pressed.

See also Digital I/O

Config single output function

Only available if Config single function is set to Toggle output function or Pulse output function.
The selected External monitored output will be pulsed or set according to the selected function.

Config double function

  • Input function – Button can be used as a digital input.

  • Single reverse – Start trigger will activate a loosening once. Next time start trigger is pressed it will do a tightening.

  • Toggle reverse – Start trigger will only start a loosening. Pressing config button twice again will make the start trigger run tightenings again.

  • Toggle vacuum – Press twice to activate the vacuum pump. Press twice again to deactivate the vacuum pump.

  • Toggle guiding light – Press twice to activate the guiding light. Press twice again to deactivate guiding light.

  • Toggle output function – Button can be used to set an external monitored output.

  • Pulse output function – Button can be used to pulse an external monitored output.

Config double input function

Only available if Config double function is set to Input function.
Sets a digital input function that will be activated as soon as button is pressed.

See also Digital I/O

Config double output function

Only available if Config double function is set to Toggle output function or Pulse output function.
The selected External monitored output will be pulsed or set according to the selected function.

Config hold function

Configurations will take effect approximately one second after pressing the button.

  • Input function – Button can now be used as a digital input.

  • Single reverse – Start trigger will activate a loosening once. Next time start trigger is pressed it will do a tightening.

  • Toggle reverse – Start trigger will only start a loosening. Pressing config button again will make the start trigger run tightenings again.

  • Toggle vacuum – Press once to activate the vacuum pump. Press again to deactivate the vacuum pump.

  • Toggle guiding light – Press once to activate the guiding light. Press again to deactivate guiding light.

  • Toggle output function – Button can be used to set an external monitored output.

  • Pulse output function – Button can be used to pulse an external monitored output.

Config hold input function

Only available if Config hold function is set to Input function.
Sets a digital input function that will be activated as soon as button is pressed.

See also Digital I/O

Config hold output function

Only available if Config hold function is set to Toggle output function or Pulse output function.
The selected External monitored output will be pulsed or set according to the selected function.

Led intensity

Sets the brightness for the LED of green, blue and red. Scale is from 1-5.

Led timeout

Sets for how many seconds the LED will be on after activating green, blue or red. Timeout can be set to 0-300 where 0 is infinity.

Led OK

  • Disabled – LED will not turn on when tightening is OK.

  • Enabled – LED will turn green when tightening is OK.

Led NOK

  • Disabled – LED will not turn on when tightening is NOK.

  • Enabled – LED will turn red when tightening is NOK.

Led batch OK

  • Disabled – LED will not turn on when batch is completed.

  • Enabled – LED will turn green or blue when batch is completed.

Led batch OK color

Only available if Led batch OK is set to enabled.

  • Green – LED will turn green when batch is completed.

  • Blue – LED will turn blue when batch is completed.

Led guiding intensity

Sets the brightness for the LED of guiding light. Scale is from 1-5.

Led guiding timeout

Sets for how many seconds the LED will be on after activating guiding light. Timeout can be set to 0-300 where 0 is infinity.

Tactile on NOK

  • Disabled – Tactile feedback is turned off.

  • Enabled – Tactile feedback is on and will make the tool vibrate if a NOK tightening where made.