Settings

Settings for ToolsTalk MT Analysis.

General settings

Parameter

Description

Path

The recording is stored to the specified folder. The files are named with an index.

The user must have write permission to the selected path.

Automatic store

Enables saving of the files to the specified folder automatically.

Show legend

Shows and hides the legend from the diagram.

Step color

The steps in a tightening program gets different colors. If disabled each graph have a unique color.

Torque trigger

Torque trigger is used to control the activation and deactivation of recordings.

Parameter

Description

Torque

The real time trace is recorded as long as the torque exceeds this value.

Start delay

The delay time can be adjusted between 0 and 50 seconds. The real time trace is recorded as long as the execution time exceeds this value. If both start delay and torque trigger is used then the real time trace will not start recording until both limits are exceeded.

Chart settings

Parameter

Description

Diagram type

Torque/Time displays the torque as a function of time.
Torque/Angle displays the torque as a function of angle.

Show torque gradient trace

Shows the torque gradient trace.