Transducer

Parameter

Description

Type

Type of transducer. For example, MT-TS

Name

Transducer name.

Max torque

Highest torque the transducer can measure.

Torque threshold

Start/Stops measurement after reaching threshold.

Torque target

What the measurement aims to reach.

Control limit

How much the measurement in % can deviate from the target/tool torque. Is also used to calculate the CMK.

Verification size

Number of measurements in the test.

Verification mode

  • Verify results - The verification result will look at each measurement to decide if the verification is OK or NOK. If one measurement is reported as NOK then the entire Verification result will be reported as NOK as well.

  • CMK - The verification result will only look at the final CMK value to decide if the verification is OK or NOK.

Minimum CMK

Minimum allowed CMK to report a verification OK. If final CMK is below this value then the verification will report a NOK.