Verification Program

The Verification program is a specific form of Psets that can be used to verify the tool accuracy together with an IAM QA controller.

A Verification program is a form of torque step with limited parameter input. The window limits will not be set on the tightening itself but can be sent to the IAM QA controller to set limits on the measured torque.

General data

Parameter

Description

Name

Is shown in Verification program list. The Verification program name is stored with the result and will be displayed in the controller result view.

Revision

Revision number of the Verification program.

Created

The date when the Verification program was created.

Modified

The date when the Verification program was last modified.

Configured tool name

The tool type the Verification program was linked to (model type in text).

Control limit

How much the reference value can deviate from:

  • Target

  • Tool (if using a transducerized tool)

  • % To calculate CMK

Verification size

Number of tightenings to perform for the testing of the tool

Verification mode

Decides what the verification result should trigger on.

  • Verify results = If one measurement result is NOK the entire verification result will report NOK.

  • CMK = If the CMK value is above the minimum CMK limit then the verification result will be OK.

Measurement Evaluation mode

The measurement will compare the Target or Tool peak value against the QA reference and the control limit to see if a measurement should be OK or NOK. Current controlled tools are locked to Target vs Reference. (read only parameter) Transducerised tools are editable and has the possibility to select between:

  • Tool vs Reference (only works when connected with USB Sync).

  • Target vs Reference.

Minimum CMK

Minimum allowed CMK value (disable chef if set to 0).

On Verification complete

Decides what shall happen after the verification program is completed.

  • Disable VProg - No Pset/Bseq is active after completion

  • Previous Pset/Bseq - Reactivate last active Pset or Batch sequence

  • Startup Pset/Bseq - Activate the Startup Pset or Batch sequence (can be setup in controller settings)

  • Keep VProg - Verification program continues to be active

Operator ID required

  • Yes = Verification on QA controller cannot start if an Operator ID is not active.

  • No = Verification on QA controller can start regardless if an Operator ID is active or not.

Step data

Parameter

Description

Speed

The speed to tool will run at during the test.

Target torque

The target torque the test shall be performed on.

Vacuum enabled

If enabled, the vacuum is activated during the test.

Step start delay

Set a start delay of the tightening