Operating the Pump

  1. Connect the gauges to the pump.

    Make sure the control valves are closed.

  2. Remove the caps from the connectors.

  3. Connect the hose to the pump and to the tool.

  4. Close the pressure relief valve.

  5. Open the control valves simultaneously to apply the pressure on the connect tools.

  6. Use the handle to build the pressure in the pump.

    The safe working pressure must be 10,000 psi (700 Bar).

  7. Close one control valve, to increase the pressure on one active tool.

Depressurizing the Pump

  1. Open both control valves slowly.

  2. Open the pressure relief valve to depressurize the system.

  3. Check the gauges and make sure the pump is depressurized before disconnecting the coupling.