EM Stop Connector Configurations

The following EM Stop connector configurations are possible:

  • EM Stop default configuration (no EM Stop connected).

  • EM Stop entry configuration - single controller with hand-held tools.

  • EM Stop entry configuration - multiple controllers with hand-held tools.

  • EM Stop entry configuration - single controller with fixtured tools.

  • EM Stop entry configuration - multiple controllers with fixtured tools.

  • EM Stop entry configuration - single controller without manual reset.

  • EM Stop bypass configuration.

  • EM Stop loopback configuration.

EM Stop Default Configuration

WARNING

For this configuration, the remote start enable switch must be set to OFF

The POWER FOCUS 8 comes with preinstalled jumpers for this configuration.

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Do not use

2

EM_STOP+

Do not use

3

EM_STOP+

Connect a jumper between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect a jumper between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Do not use

9

EM_RESET_IN

Connect a jumper between pin 9 and pin 10

10

EM_NC2

See pin 9

EM Stop Entry Configuration - Single Controller with Hand-held Tools

For this configuration, the software reset must be set to OFF.

EM Stop button connector: Phoenix, 10-pin headers, 3.5 mm pitch

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Connect a jumper between pin 1 and pin 2

2

EM_STOP+

See pin 1

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Do not use

9

EM_RESET_IN

Connect a reset button between pin 9 and 10

10

EM_NC2

See pin 9

EM Stop Entry Configuration - Multiple Controllers with Hand-held Tools

For this configuration, the software reset must be set to OFF.

Pin

Pin name

Use

1

EM_NC1

Connect a jumper between pin 1 and pin 2

2

EM_STOP+

See pin 1

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Connect a reset button between pin 8 and 9

9

EM_RESET_IN

See pin 8

10

EM_NC2

Do not use

EM Stop Entry Configuration - Single Controller with Fixtured Tools

For this configuration, the remote start enable switch must be set to ON and the software reset must be set to OFF.

Pin

Pin name

Use

1

EM_NC1

Connect a jumper between pin 1 and pin 2

2

EM_STOP+

See pin 1

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Do not use

9

EM_RESET_IN

Connect a reset button between pin 9 and 10

10

EM_NC2

See pin 9

EM Stop Entry Configuration - Multiple Controllers with Fixtured Tools

For this configuration, the remote start enable switch must be set to ON and the software reset must be set to OFF.

Pin

Pin name

Use

1

EM_NC1

Connect a jumper between pin 1 and pin 2

2

EM_STOP+

See pin 1

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Connect a reset button between pin 8 and 9

9

EM_RESET_IN

See pin 8

10

EM_NC2

Do not use

EM Stop Entry Configuration - Single Controller without Manual Reset

For this configuration, the software reset must be set to ON.

EM Stop button connector: Phoenix, 10-pin headers, 3.5 mm pitch

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Do not use

2

EM_STOP+

Do not use

3

EM_STOP+

Connect an emergency button between pin 3 and pin 4

4

24V_ISOL_EXT

See pin 3

5

EM_STOP-

Connect an emergency button between pin 5 and pin 6

6

GND

See pin 5

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Do not use

9

EM_RESET_IN

Connect a jumper between pin 9 and pin 10

10

EM_NC2

See pin 9

EM Stop Bypass Configuration

EM Stop I/O cable connector: Phoenix, 10-pin

Remove plug or use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Do not use

2

EM_STOP+

Do not use

3

EM_STOP+

Do not use

4

24V_ISOL_EXT

Do not use

5

EM_STOP-

Do not use

6

GND

Do not use

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Do not use

9

EM_RESET_IN

Do not use

10

EM_NC2

Do not use

EM Stop loopback configuration

EM Stop I/O cable connector: Phoenix, 10-pin

Use the following pin configuration:

Pin

Pin name

Use

1

EM_NC1

Do not use

2

EM_STOP+

Do not use

3

EM_STOP+

Do not use

4

24V_ISOL_EXT

Do not use

5

EM_STOP-

Do not use

6

GND

Do not use

7

EM_BYPASS_STOP-

Do not use

8

EM_BYPASS_NC

Connect a jumper between pin 8 and pin 10

9

EM_RESET_IN

Do not use

10

EM_NC2

See pin 8