Pitch Change
This strategy verifies the first point along the trace where the slope change not more than the specified slope change parameter. The trace is analyzed between the range from Residual Angle Threshold 2 to Residual Angle Threshold 1.
Parameter | Description |
|---|---|
Inspection Name | Name of the inspection. |
Torque correction coefficient | When extensions are used, the wrench measurement must be compensated to show a more accurate torque value. To calculate the correction coefficient, please refer toHow to calculate the Torque Correction Coefficient. When extensions are not used, Torque correction coefficient = 1. |
Angle correction coefficient | When extensions cause additional wrench bending, the wrench angle measurement must be compensated to show a more accurate angle value. When extensions are not used, Angle correction coefficient = 0. |
Number of sample | Number of tests to run inside the inspection. |
Cycle start | Torque value from which the test operation starts. |
Minimum torque limit | Minimum torque value that must be reached within the Target angle value in order to get an OK result. |
Maximum torque limit | Upper torque limit value. |
Change screw | If the torque applied reaches this limit, the message Change screw is shown on the wrench display. The Change screw must be equal or higher than the Maximum limit torque. |
Target torque | Torque target value. |
Torque tolerance | Tolerance that defines the maximum torque and the minimum torque according to the Target torque previously specified. Value is expressed in percentage (%). |
Final angle monitoring torque | Torque value from which the angle measurement starts (usually set to 50% of the Target torque). |
Control mode | Method to define the torque limits from the following options:
|
Residual angle threshold 1 | Maximum angle value (measured from the Final angle monitoring torque) for the residual torque when the residual torque is lower than the breakaway point. |
Residual angle threshold 2 | Maximum angle value (measured from the Final angle monitoring torque) for the residual torque when the residual torque is lower than the breakaway point. The Residual angle threshold 2 must be higher than the Residual angle threshold 1 . |
Slope change | Detect residual torque by tracking changes in angle during final tightening. It works whether the breakaway point and residual point are at the same place or not. |
Ratchet time | Starts when the torque goes below the Cycle start without reaching the 3rd percentage value. This allows the operator to release the torque for a while and recharge during the tightening operation. |


T0 | Final angle monitoring torque | T1 | Minimum torque |
a1 | Residual Angle Threshold 1 | a2 | Residual Angle Threshold 2 |
Results:
The result is the first point where the slope changes more than the allowed limit within the specified angle range.