Configuring the Tool
On the home menu, tap Configuration > Tool configuration.
On the General tab, select or clear the checkboxes to configure the following features:
Feature
Description
Vibration
Selected: Vibration device behaves according to STRwrench ongoing operation.
Clear: Vibration device is always off.
Buzzer
Selected: Audio signaling device behaves according to STRwrench ongoing operation.
Clear: Audio signaling device is always off.
Front LED
Selected: Front LED lights up when the dedicated button is pressed.
Clear: Front LED is always off.
Smart zeroing
Selected: If the STRwrench detects any movement during the zero adjustment, the zeroing procedure will start over again.
Clear: If the STRwrench detects any movement during the zero adjustment, the zeroing procedure will not start over again.
Tag
Selected: Information on the Tag is displayed and can be edited in the Integrated Controller Tool > Tool menu.
Clear: Information on the Tag is not be displayed.
On the Barcode tab, select in the dropdown list a barcode mode from the following options:
Option
Description
Disabled
The selection of inspections triggered by barcode scan is disabled.
Only local
The selection of inspections triggered by barcode scan is enabled only locally on the STRwrench.
From QAS
The selection of inspections triggered by barcode scan is enabled only on QA Supervisor.

To be read by the STRwrench scanner, a barcode must contain at least three characters.
In the top bar, tap Apply
.