Joint Parameters

Parameters marked with an asterisk (*) in the user interface are mandatory.

General category

Parameter

Description

Name

Type a name for the joint.

Description

Type a description for the joint.

Identifier

Type an identifier for the joint.

Tightening direction

In the drop-down list, select the tightening direction for the joint:

  • Clockwise.

  • Counterclockwise.

Default value: Clockwise.

Notes

Type additional notes for the joint.

Torque category

Parameter

Description

Unit of measurement

In the drop-down list, select the unit of measurement to use in the inspections linked to the joint from the following options:

  • Nm

  • dNm

  • kgf.m

  • kgf.cm

  • lbf.ft

  • lbf.in

  • ozf.ft

  • ozf.in

  • kpm

Default value: Nm.

Final angle monitoring torque

Type the torque value from which the angle measurement starts.

The Final angle monitoring torque must be ≤ Minimum torque.

Value range: 0.00 - 99999.99. Default value: 50% of the Target torque value.

Control mode

Select the method to define the torque limits from the following options:

  • Min/Max: lower and upper torque limits are the values specified respectively for Minimum torque and Maximum torque.

  • Target/Tolerance: lower and upper torque limits are determined according to the values specified for Target torque and Torque tolerance.

Default value: Target/Tolerance.

Minimum torque

Type the lower limit value for the torque.

Available only if Control mode is set to Min/Max.

Value range: 0.00 - 99999.99. Default value: 0.00.

Target torque

Type the torque target value.

Available only if Control mode is set to Target/Tolerance.

Value range: 0.00 - 99999.99. Default value: 0.00.

Maximum torque

Type the upper limit value for the torque.

Available only if Control mode is set to Min/Max.

Value range: 0.00 - 99999.99. Default value: 0.00.

Torque tolerance

Type the torque tolerance that defines the lower torque limit and upper torque limit according to the value specified for Target torque.

Available only if Control mode is set to Target/Tolerance.

Value is expressed in percentage (%).

Value range: 0.00 - 100.00. Default value: 0.00.

Angle category

Parameter

Description

Control mode

Select the method to define the angle limits from the following options:

  • Min/Max: lower and upper angle limits are the values specified respectively for Minimum angle and Maximum angle.

  • Target/Tolerance: lower and upper angle limits are determined according to the values specified for Target angle and Angle tolerance.

Default value: Target/Tolerance.

Minimum angle

Type the lower limit value for the angle.

Available only if Control mode is set to Min/Max.

Value range: 0.00 - 9999.99. Default value: 180.0.

Target angle

Type the angle target value.

Available only if Control mode is set to Target/Tolerance.

Value range: 0.00 - 9999.99. Default value: 270.0.

Maximum angle

Type the upper limit value for the angle.

Available only if Control mode is set to Min/Max.

Value range: 0.00 - 9999.99. Default value: 360.0.

Angle tolerance

Type the angle tolerance that defines the lower angle limit and the upper angle limit according to the value specified for Target angle.

Available only if Control mode is set to Target/Tolerance.

Value range: 0.00 - 10000.00. Default value: 90.0.