Maintenance Schedule

Warranty claims can only be asserted if the listed maintenance work has been carried out regularly and carefully at the specified intervals by trained personnel.

Maintenance Intervals

The below table specifies the maintenance intervals, how to do the maintenance check, and the responsible trained personnel who does the maintenance check:

Intervals

Maintenance check

Personnel

Daily

Visual inspection and clean the system

Operator

Monthly (or 100.000 Cycles)

Check and clean the system

Maintenance Expert

Yearly (or 1.000.000 cycles)

Check and clean the system

Maintenance Expert

Daily Maintenance

The below daily maintenance table specifies the components and how to do the maintenance check. Refer to the numbers from the below image:

No.

Components

Maintenance check

1

Bit/Bit Adapter

Visual inspection

2

Alignment Jaws

Clean the adhesives or other adherent impurities. For example, adhesive coatings, screw lock residues, etc.,

3

Feeding Head

Clean the adhesives or other adherent impurities. For example, adhesive coatings, screw lock residues, etc.,

4

Swivel Arm

In case of wear ,defect, or extensive impurities replace it.

5

Lines and Hoses

Visual inspection. In case of wear, defect, or extensive impurities, replace it.

Monthly Maintenance (or all 100,000 feeding cycles)

The below monthly maintenance table specifies the components and how to do the maintenance check:

No.

Components

Maintenance check

1

Bit/Bit Adapter

Visual inspection. In case of wear, defect, or extensive impurities, replace it.

6

Downholder

Check and replace the Downholder if worn out or difficult to move.

7

Tool cable

Check and replace, in case of wear and/or defect.

8

Signal lines to tightening module

Check and replace, in case of wear and/or defect.

9

Signal line to feeding unit

Check and replace, in case of wear and/or defect.

10

Feeding tube

Check if properly mounted. Replace, in case of wear and/or defect.

Yearly Maintenance (or all 1,000,000 feeding cycles)

The below yearly maintenance table specifies the components and how to do the maintenance check:

No.

Components

Maintenance check

All components from monthly Maintenance

Follow all the instructions from the monthly maintenance.

3

Swivel Arm

Check and replace, in case of wear and/or defect. Tighten the loose screws, if needed

11

Stroke Rails/Carrier

Check and clean. Lubricate the rail carrier.

12

Driving Tool

See Product Information for QST34 or Tensor SL Maintenance interval and maintenance instruction