SPC rules

  1. On the left side of the Toolbar, tap the Menu icon (). Then, select Configuration > Inspection values > SPC Rules. The following is displayed:

    A

    Save icon

    B

    Categories

    C

    Drop-down menu

    D

    Check boxes

  2. On the right side of the SPC rules page, tap the check box to enable/disable the necessary SPC rules.

    It is possible to configure different sets of rules for the Tool check, Joint check, and Dimensional check inspections by selecting the category of interest.

  3. From the Show SPC rules summary popup drop-down menu, select one of the following items:

    • Always: to always display the SPC rules summary popup with all the SPC rules.

    • NOK only: to display in the SPC rules summary popup only the NOK SPC rules.

    • Never: to never display the SPC rules summary popup.

    It is possible to configure different SPC Popup Display mode for the Tool check, Joint check, and Dimensional check inspections by selecting the category of interest.

  4. On the upper-right corner of the SPC rules page, tap the Save icon.