Open Protocol

On the left side of the Toolbar, tap the Menu icon () > Configuration > External system > Open Protocol.

  • Enabled: select the checkbox to enable the Open Protocol communication.

    By default, the Enabled checkbox is not selected.

  • Open Protocol Port: default port used for Open Protocol communication.

Tap on the Save icon to save the configuration.

Below are the available MIDs (Message Identification):

MID

Description

Revision ranges

0001

Communication start

0 ÷ 1

0002

Communication start acknowledge

0 ÷ 5

0003

Communication stop

0 ÷ 1

0004

Command error

0 ÷ 1

0005

Command accepted

0 ÷ 1

0010

Pset ID upload request

0 ÷ 1

0011

Pset ID upload response

0 ÷ 1

0014

Pset selected subscribe

0 ÷ 1

0015

Pset selected

0 ÷ 2

0016

Pset selected acknowledge

0 ÷ 1

0017

Pset selected unsubscribe

0 ÷ 1

0018

Select Pset

0 ÷ 1

0060

Last tightening result data subscribe

0 ÷ 1

0061

Last tightening result data

0 ÷ 7 (+999)

0062

Last tightening result data acknowledge

0 ÷ 1

0063

Last tightening result data unsubscribe

0 ÷ 1

0064

Old tightening result upload request

0 ÷ 1

0065

Old tightening result upload response

0 ÷ 6

0080

Read time upload request

0 ÷ 1

0081

Read time upload response

0 ÷ 1

9999

Keep alive message

0 ÷ 1