Handling Tightening Sync Mode Configuration
Double-click on a tightening Sync Mode to configure that Sync Mode.
Properties
Parameter | Description |
---|---|
Name | A user defined name for the mode. |
Description | Description of the mode. |
A tightening Sync Mode can be linked to a loosening Sync Mode. Referencing a loosening sync mode is located in the Properties menu of a tightening Sync Mode
Select the relevant loosening Sync Mode from the Loosening Sync mode drop-down.
The number of bolt configurations and the channel numbers used in the bolt configurations of the tightening Sync Mode should be the same as the loosening Sync Mode selected and a warning is displayed if they differ.
Reject management
When switch to Off:
Action if failure | Description |
End all |
|
Continue OK |
|
When switch to On:
Parameter | Description |
---|---|
Max number of failing steps | Specifies the maximum number of different steps that can fail during the whole tightening. It does not matter if the same step fail more than once, it still only counts as one failing step. |
Action if exceeded | Specifies the action if Maximum number of failing steps is exceeded. |
Action if NOK during repair | Specifies the action if a new error (NOK) is detected while a repair is ongoing. |
Triggers
To view the Sync point table a tightening program with sync points must be selected for at least one bolt in Bolt configuration.
For each synchronization point in the main path of the programs it is possible to specify different triggers to control the reject management.
Add trigger
Click on the + icon next to Add trigger.
Select trigger.
Set action for each sync point.
Delete trigger
Click on the + icon next to Add trigger.
Click on delete icon next to the trigger you want to delete.
Default trigger parameters | Description |
---|---|
Sync point | Sync point in the selected tightening program. |
Default failing | Specifies the main action if an error is detected. Is used if none of the other conditions are fulfilled. |
Default failing other | This parameter defines the action on the tools not running End or Terminate |
Number of repairs parameters | Description |
---|---|
Repairs | Specifies the maximum number of repairs that can be started from the synchronization point and if not set, an unlimited number of repairs can be made |
Repair action | Specifies the action if Maximum number of repairs have been made and a new error occurs |
Repair action other | This parameter defines the action on the tools not running End or Terminate |
NOK channels parameters | Description |
---|---|
NOK channels | Specifies the maximum number of channels that can fail in the synchronization point. If not set the number of failing channels settings will never be used to decide the action. |
NOK channel action | Specifies the action if more than NOK channels have failed in the synchronization point. |
NOK channel other | This parameter defines the action on the tools not running End NOK or Terminate NOK. |
NOK groups parameters | Description |
---|---|
NOK groups | Specifies the maximum number of groups that can fail in the synchronization point. If not set the number of failing groups settings will never be used to decide the action. |
NOK group action | Specifies the action if more than NOK groups have failed in the synchronization point. |
NOK group other | This parameter defines the action on the tools not running End NOK or Terminate NOK. |
Not repairable Parameters | Description |
---|---|
Not repairable | Specifies the action if the total status in the synchronization point is Not repairable. |
NOK repairable other | This parameter defines the action on the tools not running End or Terminate. |
Bolt configuration
To add bolt configuration, click ADD or ADD MANY. You can have maximum 64 bolt configurations.
Parameter | Description |
---|---|
Check box | Used when, for example, deleting a channel. |
Channel | Number of the channel, also named drive index. |
Tightening program | Select tightening program defined in the menu Tightening Program. |
Bolt | The actual fastener that is tightened when a tightening is made. This number will be used as the address when collecting data for the specific bolt, for example, in the fieldbus signal Bolt tightening status. |
Bolt name (optional) | Name of the bolt. |
Group | The repair groups are used to group bolts that depend on each other when running a repair. One channel can belong to none, one or more repair groups. |