Activated Joint Id - 225
Set when a compatible task is configured and running with Joint Ids. When a program or batch is started where Joint Id is used, the signal is set with the corresponding configured Joint Id for the program that's is selected by an MES/Integrator/External system. The string indicates the currently active Joint Id and not the one in a result, please see “Joint Id Result - 31046” for Joint Ids tied to specific results. If automatic incrementation is used of the Joint Id within a batch the active Joint Id will be updated when next tightening in the batch is loaded. Please see Source Tightening Properties for further information about setup of Joint Id.
Signal Type | Value Type | Size Min [bit] | Size Max [bit] |
|---|---|---|---|
State | String | 8 | 800 |
Devices
Indicator Box: FALSE
Internal I/O: FALSE
Operator Panel: FALSE
Tool Functions: FALSE
ST Selector: FALSE
Stacklight: FALSE
TLS Tag: FALSE
I/O Expander: FALSE
User Display: FALSE
Soft Selector: FALSE
Indicator Box: FALSE
Automation Rules: FALSE
Fieldbus: TRUE