PTCA - Post Thread Cut Angle
Tools |
---|
ES STR SL ST SR QST STB IXB |
This step monitor measures the maximum angle reached during the monitor and checks that it is between High limit and Low limit.
The Trigger Torque level is ignored until the end of the Thread cut angle window is reached. After that, the angle measuring starts as soon as the measured torque is above Trigger Torque.
Parameter | Description | Default value |
---|---|---|
Stop condition | It specifies where the angle measurement ends:
| Shut Off |
Trigger torque | The angle measurement starts at this trigger. Minimum limit: must be >= 0 Maximum limit: must be < Tool Max Torque | 0 |
Low Limit | Lowest acceptable angle. Minimum limit: must be >= 0 Maximum limit: must be < 9 999 999 and < High Limit | Not set |
High Limit | Highest acceptable angle. Minimum limit: Must be > 0 and > Low Limit Maximum limit: must be < 9 999 999 | Not set |
Thread cut trigger torque | Minimum limit: must be >= 0 Maximum limit: must be < Tool Max Torque | Not set |
Thread cut angle window | Minimum limit: must be >= 0 Maximum limit: must be < 9 999 999 | 0 |
Result Values
Angle Measured: the angle measured by the monitor.
A | Shut-off point | E | Angle low limit |
B | Torque trigger | F | Angle high limit |
C | Torque trigger thread cut | G | Measured angle |
D | Thread cut angle window |