PTCA - Post Thread Cut Angle

Tools

ES

STR

SL

ST

SR

QST

STB

IXB

This step monitor measures the maximum angle reached during the monitor and checks that it is between High limit and Low limit.

The Trigger Torque level is ignored until the end of the Thread cut angle window is reached. After that, the angle measuring starts as soon as the measured torque is above Trigger Torque.

Parameter

Description

Default value

Stop condition

It specifies where the angle measurement ends:

  • End
    End point used: the angle at the end of the monitor.

  • Peak Torque
    End point used: the angle at the point where the highest torque was reached during the monitor.

  • Shut Off
    End point used: the angle at the shut off point of the step.

  • Peak
    End point used: the highest angle reached during the monitor.

Shut Off

Trigger torque

The angle measurement starts at this trigger.

Minimum limit: must be >= 0

Maximum limit: must be < Tool Max Torque

0

Low Limit

Lowest acceptable angle.

Minimum limit: must be >= 0

Maximum limit: must be < 9 999 999 and < High Limit

Not set

High Limit

Highest acceptable angle.

Minimum limit: Must be > 0 and > Low Limit

Maximum limit: must be < 9 999 999

Not set

Thread cut trigger torque

Minimum limit: must be >= 0

Maximum limit: must be < Tool Max Torque

Not set

Thread cut angle window

Minimum limit: must be >= 0

Maximum limit: must be < 9 999 999

0

Result Values

  • Angle Measured: the angle measured by the monitor.

Point and click on image to see more information:
Step Monitor - Post Thread Cut Angle