Tool Configuration - Function Button

Use the tool's Function Button to control up to six of the available input signals. The buttons have three possible condition states that are combined with the two possible states of the direction switch.

Function button states

Direction switch states

Pressed

CW

Single push

CW

Double push

CW

Pressed

CCW

Single push

CCW

Double push

CCW

Two configurable parameters controls the push time.

Parameter

Description

Default value

Push detection interval (ms)

For single push: the maximum push time (in milliseconds) between the button being pressed and the button being released.

300 ms

Next push interval (ms)

For double push: the maximum time (in milliseconds) between the button being released after the first push, and the button being pressed again.

300 ms