Tool Configuration - Function Button
Use the tool's Function Button to control up to six of the available input signals. The buttons have three possible condition states that are combined with the two possible states of the direction switch.
Function button states | Direction switch states |
---|---|
Pressed | CW |
Single push | CW |
Double push | CW |
Pressed | CCW |
Single push | CCW |
Double push | CCW |
Two configurable parameters controls the push time.
Parameter | Description | Default value |
---|---|---|
Push detection interval (ms) | For single push: the maximum push time (in milliseconds) between the button being pressed and the button being released. | 300 ms |