Rundown Parameters

All rundown parameters

Parameter name

Condition

Description

Default value

Self-tap

 

Self-tap is activated through a switch

Off: Self-tap is turned off.

On: Self-tap is turned on.

Off

Length

Self-tap = On

Defines the angle to turn the socket during Self-tap. Measured from the end of the Start step.

360°

Speed

Self-tap = On

Defines the speed during Self-tap

 

Torque min

Self-tap = On

Torque value for lower Self-tap limit.

0 Nm

Torque max

Self-tap = On

Torque value for upper Self-tap limit.

Tool max torque

Rundown torque limits

 

Rundown torque limits is activated through a switch

Off: Rundown torque limits is turned off.

On: Rundown torque limits is turned on.

Off

Offset

Rundown torque limits = On

Angle offset before the Angle interval begins.

Length

Rundown torque limits = On

Angle defining the Rundown torque limit section.

360°

Torque min

Rundown torque limits = On

Torque value for lower Rundown torque limit.

0 Nm

Torque max

Rundown torque limits = On

Torque value for upper Rundown torque limit.

% of target torque

Rundown angle limits

 

Rundown angle limits is selected from a shortcut menu.

Off: Rundown angle limits is turned off.

From Trigger: Rundown angle limits is turned On. The system starts to monitor the tightening angle as soon as the tool trigger is pressed and reports if angle limits are violated.

From torque: Rundown angle limits is turned On. The system starts to monitor the tightening angle from the specified torque value and reports if angle limits are violated.

Off

Rundown angle monitoring torque

Rundown angle monitoring torque = From torque

Torque value from where Rundown angle limits are set

 

Angle min

Rundown angle limits = On

Angle value for lower angle limit from starting point

100°

Angle max

Rundown angle limits = On

Angle value for upper angle limit from starting point

1000°

Time min

Rundown angle limits = On

Minimum time for the step

10 ms

Time max

Rundown angle limits = On

Maximum time for the step

5000 ms

Post view torque

 

Post view torque is activated through a switch

Off: Post view torque is turned off.

On: Post view torque is turned on.

Off

Torque min

Post view torque = On

Torque value for lower Post view torque limit.

 

Torque min offset

Post view torque = On

Angle offset before the Post view torque min interval begins.

720°

Torque min length

Post view torque = On

Angle length defining the Post view torque min section

90°

Torque max

Post view torque = On

Torque value for upper Post view torque limit.

 

Torque max offset

Post view torque = On

Angle offset before the Post view torque max interval begins.

360°

Torque max length

Post view torque = On

Angle length defining the Post view torque max section

90°

Compensate value

Post view torque = On

The Compensate value is selected from a shortcut menu.

Rundown complete torque

 

Defines the torque value for when snug is reached and the rundown is completed. The program can then move on to tightening the screw. Rundown complete must be less than First torque in multi-step strategies or Target torque in the TurboTight strategy.