Enabling and Disabling the Tightening Settings
The General Virtual Station configuration contains a tightening section, which is used to set parameters for Disable tightening and Disable loosening.
Select a controller in the Plant structure .
Go to the Configurations tab in the menu bar.
The workspace area displays the available Configurations.
Double-click on an existing General Virtual Station to configure, or select Add to create a new one to configure.
Make the relevant selections in the Tightening Settings parameters, according to the information in the tables below.
Parameter Value | Description |
---|---|
Off | A disabled tool will remain disabled regardless of the loosening status. |
On OK | A disabled tool will be unlocked after an OK loosening has been performed. |
Always | A disabled tool will be unlocked as soon as a loosening has been performed, regardless of the loosening status. |
Disable loosening | Description |
---|---|
Off | Disable loosening is Off. An operator can always loosen a screw. |
On OK tightening | Disable loosening for an OK tightening. An operator cannot loosen a screw that was terminated with tightening OK. |
On NOK tightening | Disable loosening for an NOK tightening. An operator cannot loosen a screw that was terminated with tightening NOK. |
Always | Disable loosening is always ON. An operator can never loosen a screw. |
Disable tightening | Description |
---|---|
Off | Disable tightening is Off. An operator can always tighten a screw. |
On OK tightening | Disable tightening after an OK tightening. An operator cannot tighten another screw if the current tightening terminated with OK. |
On NOK tightening | Disable tightening after a NOK tightening. An operator cannot tighten another screw if the current tightening terminated with NOK. |
After every tightening | Disable tightening is activated after every tightening. An operator cannot tighten another screw until the current tightening is terminated. |
Tool lock behavior
Tool lock behavior is set to Off by default. This behavior can be overridden to allow the tool to be unlocked by the operator by performing a loosening.
Allowing a disabled tool to unlock after loosening
In the configuration used by the tool (set in the Virtual Station the tool is connected to), set the Unlock tool on loosening to On OK or Always.
In order to enable the setting above, three conditions need to be met:
1. The Disable loosening parameter cannot be set to Off or Always.
2. The Disable loosening value cannot be set to the same value as the Disable tightening.
3. The tightening program used must have loosening enabled.
When the tool is locked for either tightening or loosening due to a disable state, it can be unlocked by any of the following input signals:
Master_Unlock
Unlock_Tool_On_Disable
This input signal can be sent to the controller either from an accessory, from a programable tool accessory, or from the Fieldbus unit.