Result Reporters

The result reporters makes it possible to extract specific values of selected producer from the result. The result reporters belong to a step but has to be tied to the monitor/restriction from which they will read the values. Only monitors or restrictions located in the same step as the result reporter can be selected. A result reporter is added to a step using drag and drop (in the same way as monitors and restrictions). Each result reporter is responsible for reporting a specific result value, for example, Rundown Angle, Final Torque, Prevailing Torque.

It is possible to tie a result reporter to:

  • program monitors

  • step monitors

  • step restrictions

Each result reporter defines a final value type:

  • FA – Final Angle

  • FC – Final Current

  • FT – Final Torque

  • PT – Prevailing Torque

  • RA – Rundown Angle

  • ST – Self-tap Torque

General Parameters

Parameter

Description

Producer

Specifies which monitor/restriction produces the value.

Value

Specifies which value to show from the selected producer.

Limitations:

  • It is only possible to add a result reporter on a monitor/restriction belonging to a step in main path or a program monitor/program restriction.

  • There may exist several reporters on a step if they are of different type.

  • There may exist a result reporter of for example type final angle on every step and program monitor angle.

  • For those monitor/restrictions that have more than one result value it is possible to add more than one result reporter if the result reporters are of different types.

  • There may not exist several result reporters of the same type on a step or on a program monitor/restriction.

  • There is only one result reported for each possible final value type.

Rules:

  • The internal number of a result item has to be the same as for the corresponding result reporter.

  • The internal number of a monitor/restriction result has to be the same as the internal number of the monitor/restriction in the configuration.

  • The step results has to be ordered according to the order of execution. The first executed step has to be first.

Possible values reported by a result reporter if present in the monitor/restriction/step:

  • The monitors/restrictions measured value (as float or integer)

  • The monitors/restrictions high and low limits

  • Status

  • Torque trigger and angle trigger

  • Angle target and torque target (read from the step)

Possible values for status:

  • Low

  • OK

  • High

  • Other

  • NotSet

The target values do not belong to any step monitor so the target values are taken from the step that the monitor belongs to.