Virtual Station Mapping Configuration

A virtual station in a controller and the fieldbus master communicate by exchanging a fieldbus map between each other.

One or more fieldbus maps are combined into a Process Data Frame, which is sent on the physical communication link between the controller and the fieldbus master.

Fieldbus Virtual Station Mapping Configuration

Column

Function

Check box

Select or deselect a mapping.

Virtual station

Name of virtual station.

Fieldbus configuration

The fieldbus map.

To/From controller offset

Starting point of the fieldbus map within the Process Data Frame.

Acyclic Virtual Station Mapping Configuration

Column

Function

Check box

Select or deselect a mapping.

Virtual station

Name of virtual station.

Acyclic configuration

The acyclic data map.

Start Instance

First instance number of the acyclic data. Default/minimum instance number: 2048.

End Instance

Last instance number of the acyclic data. Maximum instance number: 65535.

The maximum size of the instance varies between the different fieldbus types.

No of Instances

Number of instances that are required to send the acyclic data. For example, if the Data instance size is set as 64 and the Start Instance is 2048 and the End Instance is 2060, then the No of instances are 13 and the maximum size for the acyclic configuration will be 832 bytes . The No of instances are generated automatically based on the Start Instance and End Instance.

Size in Bytes

Maximum size of the acyclic configuration based on the selected Data instance size, Start Instance and the End Instance.

The total size of the acyclic data should not exceed 65536 bytes.

A virtual station can only have one acyclic fieldbus configuration mapped, but an acyclic fieldbus configuration can be mapped to many virtual stations.