Input Signals
Abort Sequence - 10012
Acknowledge Events - 10004
Activate Tool Scanner - 10075
Batch Decrement - 10002
Batch Increment - 10001
Bypass Tightening Program - 10008
Disable Fieldbus - 10049
Disable tool - 30000
Disable Tool Scanner - 10119
Dynamic Batch Size - 10074
External OK - 10063
Fieldbus Lock Loosening - 20021
Fieldbus Lock Tightening - 20020
Flush Read Result Queue - 30005
Select Input Bit 4 - 10066
ID for Dynamic Batch Size - 10073
Lock Loosening - 20003
Lock Tightening - 20002
Lock Tool Active High - 20004
Lock Tool Active Low - 20061
Manual Mode - 10061
Master Unlock - 10005
Pulse Stop - 10030
Read Result Handshake Ack - 30004
Reset All Identifiers - 10115
Reset Batch - 10003
Reset Batch Sequence - 10053
Reset Bistable Relay - 10022
Reset Latest Identifier - 10114
Reset Relays - 10120
Reset Sequence Status - 10118
Reset Too Many NOK - 10013
Select Input - 10020
Select Input and Dynamic Batch Size - 30007
Select Input Bit 0 - 10016
Select Input Bit 1 - 10017
Select Input Bit 2 - 10018
Select Input Bit 3 - 10019
Select Input Bit 5 - 10067
Select Input Bit 6 - 10068
Select Input Bit 7 - 10069
Select Input Bit 8 - 10070
Select Input Bit 9 - 10071
Select Loosening - 10029
Select Next Identifier Number - 10116
Select Previous Identifier Number - 10117
Set Bistable Relay - 10021
Socket Selector External Green Light - 10046
Socket Selector External Red Light - 10047
Start Loosening - 10011
Start Tightening - 10010
Start Tightening Pulse - 10024
Start Tools - 10028
To SoftPLC - 10065
Unlock Tool on Complete - 10051
Unlock Tool on Disable - 10059
Output Signals
Active Identifier String - 186
Active Identifier String 1 - 188
Active Identifier String 2 - 189
Active Identifier String 3 - 190
Active Identifier String 4 - 191
Batch Completed - 30
Batch Completed NOK - 37
Batch Completed OK - 36
Batch Count - 31
Batch Running - 32
Batch Sequence Completed NOK - 46
Batch Sequence Completed OK - 45
Batch Sequence Done - 48
Batch Sequence Running - 47
Bistable Relay - 40
Calibration Alarm - 138
Configuration Version - 88
Controller Switched On - 42
Current Running Batch - 180
Direction Switch CCW - 13
Direction Switch CW - 12
Emergency Stop - 20036
Event Code - 30001
Event Code Severity - 30003
Event Present - 161
Fieldbus Disconnected - 96
Final Angle - 31003
Final Angle - 8
Final Angle Status - 31006
Final Measured Current - 31017
Final Target Speed - 31020
Final Target Torque - 31015
Final Torque - 31002
Final Torque - 5
Final Torque Status - 31009
First Target Torque - 31019
From SoftPLC - 10064
High Angle - 10
High Torque - 7
Identifier Received - 100
Last Received Identifier String - 187
License Server Connection Lost - 134
Loosening Disabled - 184
Loosening Enabled - 185
Loosening is Locked - 28
Loosening NOK - 74
Loosening OK - 70
Low Angle - 9
Low Torque - 6
Manual Mode - 101
Max Consecutive NOK Reached - 35
Open End in Open Position - 89
Open Protocol Disconnected - 95
Pass-Through Identifier - 104
Program End - 168
Program Start - 132
Pulse Tool Alarm Oil Level Empty - 167
PVT Compensate Value - 31029
Read Result Queue Flushed - 30006
Ready to Start - 29
Received Identifier 1 - 192
Received Identifier 2 - 193
Received Identifier 3 - 194
Received Identifier 4 - 195
Rehit - 31014
Remaining Batch - 33
Rundown Angle - 31038
Rundown Angle High - 165
Rundown Angle Low - 166
Selected Sequence Bit 0 - 139
Selected Sequence Bit 1 - 140
Selected Sequence Bit 2 - 141
Selected Sequence Bit 3 - 142
Selected Sequence Bit 4 - 143
Selected Sequence Bit 5 - 144
Selected Sequence Bit 6 - 145
Selected Sequence Bit 7 - 146
Selected Sequence Bit 8 - 147
Selected Sequence Bit 9 - 163
Selected Sequence Id - 84
Selected Tightening Program - 69
Selected Tightening Program Bit 0 - 148
Selected Tightening Program Bit 1 - 149
Selected Tightening Program Bit 2 - 150
Selected Tightening Program Bit 3 - 151
Selected Tightening Program Bit 4 - 152
Selected Tightening Program Bit 5 - 153
Selected Tightening Program Bit 6 - 154
Selected Tightening Program Bit 7 - 155
Selected Tightening Program Bit 8 - 156
Selected Tightening Program Bit 9 - 157
Sequence Aborted - 160
Service Indicator Alarm - 137
Size of Sequence - 181
Socket Selector Disconnected Lock - 20039
Software Major Version - 86
Software Minor Version - 87
Software Release Version - 85
Start Final Angle - 31016
Station Ready - 71
Thread Direction CCW - 26
Tightening Date Day - 31032
Tightening Date Month - 31033
Tightening Date Year - 31034
Tightening Disabled - 182
Tightening Done - 31010
Tightening Enabled - 183
Tightening is Locked - 27
Tightening NOK - 4
Tightening OK - 3
Tightening Program Max Angle - 31004
Tightening Program Max Torque - 31007
Tightening Program Min Angle - 31005
Tightening Program Min Torque - 31008
Tightening Time - 31031
Tightening Time High - 135
Tightening Time Hour - 31035
Tightening Time Low - 136
Tightening Time Minute - 31037
Tightening Time Second - 31036
Tool Battery Low - 90
Tool Connected - 73
Tool Disabled - 158
Tool Enabled - 159
Tool Function Button Pressed - 179
Tool Health OK - 103
Tool Loosening - 22
Tool Rotation CCW - 25
Tool Rotation CW - 24
Tool Running - 23
Tool Serial Number Numeric - 31021
Tool Tag Identifier - 94
Tool Tightening - 21
Total Number of Tightenings - 31018
Trigger pressed - 11
Virtual Station Name - 105
Input/Output Signals
Clear Results - 39
Disable Open Protocol Commands - 10060
External Identifier - 10045
External Monitored 1 - 10035
External Monitored 2 - 10036
External Monitored 3 - 10037
External Monitored 4 - 10038
External Monitored 5 - 10039
External Monitored 6 - 10040
External Monitored 7 - 10041
External Monitored 8 - 10042
Fieldbus Keep Alive - 30002
Generic IO 1 - 50
Generic IO 10 - 59
Generic IO 2 - 51
Generic IO 3 - 52
Generic IO 4 - 53
Generic IO 5 - 54
Generic IO 6 - 55
Generic IO 7 - 56
Generic IO 8 - 57
Generic IO 9 - 58
Generic Rising Edge 1 - 169
Generic Rising Edge 10 - 178
Generic Rising Edge 2 - 170
Generic Rising Edge 3 - 171
Generic Rising Edge 4 - 172
Generic Rising Edge 5 - 173
Generic Rising Edge 6 - 174
Generic Rising Edge 7 - 175
Generic Rising Edge 8 - 176
Generic Rising Edge 9 - 177
Event Codes
Input Signals Used by the Fieldbus
Smart Connected Information
Download
Download All For Offline Use – PC Only
Print
Print this Topic
Print this Section
Print All
Language
US-English (en-US)
Česky (cs-CZ)
Deutsch (de-DE)
Español (es-ES)
Français (fr-FR)
Italiano (it-IT)
日本語 (ja-JP)
한국어 (ko-KR)
Português (Brasil) (pt-BR)
Svenska (sv-SE)
简体中文 (zh-CN)
Language
US-English (en-US)
Česky (cs-CZ)
Deutsch (de-DE)
Español (es-ES)
Français (fr-FR)
Italiano (it-IT)
日本語 (ja-JP)
한국어 (ko-KR)
Português (Brasil) (pt-BR)
Svenska (sv-SE)
简体中文 (zh-CN)
Print this Topic
Print this Section
Print All