Fieldbus parameters for EtherNet/IP
Field | Description | Default value |
---|---|---|
Fieldbus type | Type is selected from drop-down menu. The following parameters depend on the selected type. EtherNet/IP | None |
Update interval | How often a Process Data Frame is sent. The value is expressed in milliseconds. Minimum value is 100 ms. |
|
Lock tool when fieldbus offline | Selection switch Off-On. Determines the action taken by the controller if the fieldbus module loses communication with the fieldbus master (SoftPLC). | Off |
Read result handshake | Selection switch Off-On. When turned On, the setting will affect all virtual stations. The signal Read Result Handshake has to be mapped in the fieldbus configuration. Any results produced when there are no results to acknowledge will immediately be sent to the SoftPLC. Results to acknowledge will be put in a queue and when acknowledged it will be cleared and the next result in the queue is sent. The time between the cleared result and the next result in the queue is dependent on the cycle time for the fieldbus set in the general fieldbus settings. If the setting is changed, or if the fieldbus mapping for the virtual station is changed, the results still in the queue will be flushed and not sent to the PLC. | |
Set by network | Selection switch Off-On. Determines how the fieldbus module communication is configured.
| Off |
Fieldbus node IP address | Format is 0.0.0.0 |
|
Subnet mask | Format is 0.0.0.0 |
|
Gateway | Format is 0.0.0.0 |
|
To controller | Total receive Process Data Frame. The frame size is a combination of all the virtual station receive frames. The size is expressed in number of bytes. | |
From controller | Total transmit Process Data Frame. The frame size is a combination of all the virtual station transmit frames. The size is expressed in number of bytes. |