Input signals

Code

Input signal

Type

Description

PF 6000

10001

Batch increment

Event

Incrementally increases the batch counter by one.

X

10002

Batch decrement

Event

Incrementally decreases the batch counter by one.

X

10003

Reset batch

Event

Resets the batch counter to 0. No batch OK (nxOK). If batch OK is activated it will be deactivated.

X

10004

Acknowledge events

Event

Acknowledgement of an event.

X

10005

Master unlock

Event

Unlocks most locks defined in lock page.

X

10006

Barcode

Event

Generated for example when a USB barcode scanner has scanned a barcode.

X

10007

Stop drive

Event

Only controller internal use, used by locks to stop ongoing tightenings, see Lock tab

X

10008

Bypass tightening program

Event

Skips the next tightening program in the running Batch sequence.

X

10010

Start tightening

State

Active signal starts tightening. Once input goes inactive the tightening must be stopped.

X

10011

Start loosening

State

Active signal starts loosening. Once digital input goes inactive the loosening must be stopped.

X

10012

Abort sequence

Event

When a Batch sequence abort request is received, the Batch sequence functionality will wait for completion of the ongoing tightening result before aborting the Batch sequence.

X

10013

Reset Too many NOK

Event

Reset the batch after receiving lock Too Many NOK.

X

10014

Socket lifted

State

Is generated when a unique socket is lifted on socket selector (integer = socket ID), no socket is lifted (integer = 0) or when more than one is lifted (integer = 0).

X

10015

Protocol Message Ready

Event

Reported when a message is in queue from protocol.

X

10016

Select input bit 0

State

Input signal for select bit 0.

X

10017

Select input bit 1

State

Input signal for select bit 1.

X

10018

Select input bit 2

State

Input signal for select bit 2.

X

10019

Select input bit 3

State

Input signal for select bit 3.

X

10020

Select input

State

Input selected value.

X

10021

Set bistable relay

Event

Set the Bistable relay output.

X

10022

Reset bistable relay

Event

Reset the Bistable relay output.

X

10024

Tightening pulse start

Event

The tightening starts at signal. Runs until the tightening is finished, or until the 30 sec timeout in tightening program occurs.

X

10028

Start drive

State

Active signal starts the tool (default operation mode is tightening). As soon as signal goes inactive the tool must be stopped. Used in combination with 10029 (Select loosening).

X

10029

Select loosening

State

Selects loosening as default operation mode and used in combination with 10028 (Start drive).

X

10030

Pulse stop

Event

If this signal is generated any ongoing tightening will be stopped. Used in combination with 10024.

X

10035

External monitored 1

State

X

10036

External monitored 2

State

X

10037

External monitored 3

State

X

10038

External monitored 4

State

X

10039

External monitored 5

State

X

10040

External monitored 6

State

X

10041

External monitored 7

State

X

10042

External monitored 8

State

X

10043

Socket lifted raw

State

X

10045

External Identifier

State

Provide up to 2 identifiers to be passed from Fieldbus for task selection.

X

10046

Socket Selector External Green Light

State

Controls green lights when socket selector is in external mode (how multiple physical devices are mapped to logical sockets are defined by the socket selector resource configuration)Byte0 - logical sockets 1-4Byte1 - logical sockets 5-8Byte2 - logical sockets 9-12Byte3 - logical sockets 13-16(2 bits per socket, 00=off, 01=flash, 10=solid)

X

10047

Socket Selector External Red Light

State

Controls red lights when socket selector is in external mode. See 10046 for details.

X

10048

Soft select input value

State

Input soft select value

X

10049

Disable Fieldbus

State

Disables the fieldbus.

X

10050

User ID

State

User ID

X

10051

Unlock tool on complete

Event

Unlocks a tool that is locked by Tool Lock on Complete.

X

10053

Reset batch sequence

Event

Resets the batch sequence. Unlocks a tool that is locked by Tool Lock on Complete.

X

10058

Flash Tool Green Led

Event

X

10059

Unlock tool on disable

Event

X

10060

Disable Open Protocol Commands

State

X

10061

Manual mode

State

X

10063

External OK

Event

X

10066

Select input bit 4

State

X

10067

Select input bit 5

State

X

10068

Select input bit 6

State

X

10069

Select input bit 7

State

X

10070

Select input bit 8

State

X

10071

Select input bit 9

State

X

10073

Tightening program ID for Dynamic batch size

State

X

10074

Set dynamic batch size

State

X

10075

Activate tool scanner

Event

Input signal to activate the tool scanner from an external source.

X

10105

Reset result data

State

Reset result data

X

10114

Reset latest identifier

Event

resets the latest identifier

X

30000

Disable tool

State

Immediately stops and locks the tool.

X

30004

Read Result Handshake

State

X

30005

Result Queue Flush

Event

X

30007

Select Tightening program and set batch size

State

X