Input signals
Code | Input signal | Type | Description | PF 6000 |
---|---|---|---|---|
10001 | Batch increment | Event | Incrementally increases the batch counter by one. | X |
10002 | Batch decrement | Event | Incrementally decreases the batch counter by one. | X |
10003 | Reset batch | Event | Resets the batch counter to 0. No batch OK (nxOK). If batch OK is activated it will be deactivated. | X |
10004 | Acknowledge events | Event | Acknowledgement of an event. | X |
10005 | Master unlock | Event | Unlocks most locks defined in lock page. | X |
10006 | Barcode | Event | Generated for example when a USB barcode scanner has scanned a barcode. | X |
10007 | Stop drive | Event | Only controller internal use, used by locks to stop ongoing tightenings, see Lock tab | X |
10008 | Bypass tightening program | Event | Skips the next tightening program in the running Batch sequence. | X |
10010 | Start tightening | State | Active signal starts tightening. Once input goes inactive the tightening must be stopped. | X |
10011 | Start loosening | State | Active signal starts loosening. Once digital input goes inactive the loosening must be stopped. | X |
10012 | Abort sequence | Event | When a Batch sequence abort request is received, the Batch sequence functionality will wait for completion of the ongoing tightening result before aborting the Batch sequence. | X |
10013 | Reset Too many NOK | Event | Reset the batch after receiving lock Too Many NOK. | X |
10014 | Socket lifted | State | Is generated when a unique socket is lifted on socket selector (integer = socket ID), no socket is lifted (integer = 0) or when more than one is lifted (integer = 0). | X |
10015 | Protocol Message Ready | Event | Reported when a message is in queue from protocol. | X |
10016 | Select input bit 0 | State | Input signal for select bit 0. | X |
10017 | Select input bit 1 | State | Input signal for select bit 1. | X |
10018 | Select input bit 2 | State | Input signal for select bit 2. | X |
10019 | Select input bit 3 | State | Input signal for select bit 3. | X |
10020 | Select input | State | Input selected value. | X |
10021 | Set bistable relay | Event | Set the Bistable relay output. | X |
10022 | Reset bistable relay | Event | Reset the Bistable relay output. | X |
10024 | Tightening pulse start | Event | The tightening starts at signal. Runs until the tightening is finished, or until the 30 sec timeout in tightening program occurs. | X |
10028 | Start drive | State | Active signal starts the tool (default operation mode is tightening). As soon as signal goes inactive the tool must be stopped. Used in combination with 10029 (Select loosening). | X |
10029 | Select loosening | State | Selects loosening as default operation mode and used in combination with 10028 (Start drive). | X |
10030 | Pulse stop | Event | If this signal is generated any ongoing tightening will be stopped. Used in combination with 10024. | X |
10035 | External monitored 1 | State | X | |
10036 | External monitored 2 | State | X | |
10037 | External monitored 3 | State | X | |
10038 | External monitored 4 | State | X | |
10039 | External monitored 5 | State | X | |
10040 | External monitored 6 | State | X | |
10041 | External monitored 7 | State | X | |
10042 | External monitored 8 | State | X | |
10043 | Socket lifted raw | State | X | |
10045 | External Identifier | State | Provide up to 2 identifiers to be passed from Fieldbus for task selection. | X |
10046 | Socket Selector External Green Light | State | Controls green lights when socket selector is in external mode (how multiple physical devices are mapped to logical sockets are defined by the socket selector resource configuration)Byte0 - logical sockets 1-4Byte1 - logical sockets 5-8Byte2 - logical sockets 9-12Byte3 - logical sockets 13-16(2 bits per socket, 00=off, 01=flash, 10=solid) | X |
10047 | Socket Selector External Red Light | State | Controls red lights when socket selector is in external mode. See 10046 for details. | X |
10048 | Soft select input value | State | Input soft select value | X |
10049 | Disable Fieldbus | State | Disables the fieldbus. | X |
10050 | User ID | State | User ID | X |
10051 | Unlock tool on complete | Event | Unlocks a tool that is locked by Tool Lock on Complete. | X |
10053 | Reset batch sequence | Event | Resets the batch sequence. Unlocks a tool that is locked by Tool Lock on Complete. | X |
10058 | Flash Tool Green Led | Event | X | |
10059 | Unlock tool on disable | Event | X | |
10060 | Disable Open Protocol Commands | State | X | |
10061 | Manual mode | State | X | |
10063 | External OK | Event | X | |
10066 | Select input bit 4 | State | X | |
10067 | Select input bit 5 | State | X | |
10068 | Select input bit 6 | State | X | |
10069 | Select input bit 7 | State | X | |
10070 | Select input bit 8 | State | X | |
10071 | Select input bit 9 | State | X | |
10073 | Tightening program ID for Dynamic batch size | State | X | |
10074 | Set dynamic batch size | State | X | |
10075 | Activate tool scanner | Event | Input signal to activate the tool scanner from an external source. | X |
10105 | Reset result data | State | Reset result data | X |
10114 | Reset latest identifier | Event | resets the latest identifier | X |
30000 | Disable tool | State | Immediately stops and locks the tool. | X |
30004 | Read Result Handshake | State | X | |
30005 | Result Queue Flush | Event | X | |
30007 | Select Tightening program and set batch size | State | X |