Installing the Station Setup Application

The condensed Station Setup installation has full controller configuration functionality, but also some limitations:

  • The entire installation has a smaller footprint and is installed on a portable computer.

  • Only one physical controller can be managed at a time.

  • The computer is connected to the service port of the controller to avoid interruption of normal activity.

Applications

The typical application for this mode of operation can be the following:

  • A small installation with few controllers when the ToolsTalk 2 functionality is desired but may not have a business justification.

  • Atlas Copco service personnel can access a controller using ToolsTalk 2 without connecting to the customer network but instead using the service port of the controller.

  • Offline configuration of controllers using the controller library features. The configuration file can later be transferred to a real controller for verification.

  • An easy export of a controller configuration that is very helpful in debugging tasks.

Before you begin with the ToolsTalk 2 Station Setup installation, make sure all the requirements are met as described in section Before installing.

  1. Place the executable file ToolsTalkStationSetup<xxx>.exe in a folder on your computer. The <xxx> represents the version of the file.

  2. Double-click on the executable file.

If an error occurs during installation, a step is unclear, or a parameter name or value is unclear, look for more information in the Troubleshooting section.

Screen

Parameters

Welcome to the InstallShield Wizard

Select Next.

License Agreement

Shown if it is a new Station Setup installation.

Accept the license agreement.

Select Next.

Destination Folder

Shown if it is a new Station Setup installation.

A default folder is provided for the program installation, but this can be changed.

The folder destination must not be changed during a ToolsTalk 2 upgrade.

Select Next.

Application settings

ToolsTalk Settings:

  • Set the Web Application Port value : Default is set to 9101.

  • Set the username to ToolsTalkOfflineUser.

Select Next.

Database Server

Select the database server from the drop-down menu (recommendation is to use local), or browse to another server.

Connect using:

  • Login Id: Enter the login Id for the selected SQL database.

  • Password: Enter the password for the SQL database.

Use the default ACDC Database location provided C:\AtlasCopco_ACDC_Database\, or select Browse to choose a different location for the database server.

Select the Test DB Connection button to verify that the ToolsTalk 2 application connects with the SQL database.

Select Next.

Ready to Install the program

Select Install.

InstallShield Wizard Completed

Select Finish.