Fieldbus Configuration Library - Creating a Global Fieldbus Configuration from an Existing Fieldbus Configuration
- Select a controller (containing the desired fieldbus configuration) in the Plant structure workspace  . .
- Select Fieldbus & SoftPlc  in the menu bar. in the menu bar.
- In the Fieldbus menu select one or more fieldbus signal configurations to add to the library. Select Manage then Add to library from the drop-down menu. - The Create global configuration dialog window opens. Select Create. 
 
- The selected local configuration will become a global configuration, stored in the Global Fieldbus configuration library. - If local changes are made in the controller or web GUI, the two options below are available: - Auto revert: Changes in the controller will not apply to the global fieldbus configuration, the global configurations will still be applied. 
- Unlink: Changes in the controller will apply to the fieldbus configuration in the controller, and the link to the global configuration will be cut. As a result, the global fieldbus configuration is immediately removed from the distribution list to the controller. 
 
- Select Library  in the left-side menu bar. in the left-side menu bar.
- Go to Global fieldbus library  . .- The workspace shows a list of Global fieldbus configurations and the newly added fieldbus configuration is now visible in the list.