Bolt or Channel Area Overview
In the bolt or channel configuration area, it is possible to configure the acyclic data items of the following types for a bolt or a channel:
- MultiStage tightening 
- Program monitor 
- Program restriction 
- Step monitor 
- Step restriction 
| Parameter name | Description | 
|---|---|
| Type | Value type of each item. Example: MultiStage tightening, Program monitor, Program restriction, Step monitor or Step restriction. | 
| Offset | Item position in the acyclic data frame and is defined in bytes. | 
| Size | Size in bytes. It is possible to configure this manually if the datatype is a string. If the datatype is not a string, the values are set automatically based on the data type. | 
| Data type | Data type values. Example: String, Int8, Int16 and so on. | 
| Name | Item name. Non editable. | 
| Identifier | Sets the ID of the bolt or channel selected. |