PTCA - Post Thread Cut Angle

Tools

ES

STR

SL

ST

SR

QST

STB

IXB

Measures the angle achieved during the monitoring and checks that it is between the specified angle limits. The Trigger Torque level is ignored until the end of the Thread cut angle window is reached. After that, the angle measuring starts as soon as the measured torque is above Trigger Torque. The parameter Stop Condition specifies where the angle measurement should end.

Parameter

Description

Trigger torque

Must be >= 0

Thread cutting angle window

Must be > 0

Angle measurement type

Peak angle

Angle at peak torque

Shut off angle

Angle at end

Thread cut trigger torque

Must be >= 0

Low Limit

Must be >= 0

High Limit

Must be > 0

Must be > Low limit