T|A – Tighten to Torque or Angle

Tools

ES

STR

SL

ST

SR

QST

STB

IXB

This step runs the tool with the speed n in the forward direction until the first of either torque target or angle target is reached. The torque and angle measurements start at the beginning of the step.

Parameter

Description

Target torque

Must be > 0.

Target angle

Must be > 0.

Speed

Default: 60 rpm. Must be > 0.

Speed ramp type

Hard, soft, or manual. Default: Hard. If you select Manual, the Speed ramp field opens.

Speed ramp

If Speed ramp type is Manual, this field opens. Default: 500 rpm/s.

Brake

(Valid only for Power Focus 6000 StepSync, Power Focus 8 StepSync, and Flex).

If On the tool will be stopped when the target is reached.

If Off the program goes directly to the next step without stopping the tool.