Connecting the Screw Feeding Tightening Module to Pneumatic Air Supply and Connecting Line

WARNING

Compressed Air

High air pressure can cause severe damage and bodily injury.

  • Do not exceed maximum air pressure.

  • Make sure that there are no damaged or loose hoses or fittings.

Preparing the Connecting Module

  1. Remove the Cover (green) on the Connecting Module by removing 2 hex head screws (green).

  2. Remove 1 hex head screw (blue) on the Clip for cable and hose guidance (blue).

  3. Open the upper bracket of the Clip for cable and hose guidance (blue) on the Driving Tool.

Air supply for Forward Stroke and Return Stroke

  • Black Hose for Forward Stroke (blue arrow)

  • Yellow Hose for Return Stroke (green arrow)

Attaching the Connecting Line

  • Gray cable

  1. From the Screw Feeding Unit, connect the Forward and Return Stroke Hoses to the corresponding connectors (observe the direction arrows at the top of the Connecting Module or color markings).

  2. Attach the Connecting Line from the Screw Feeding Unit to the plug (3-pin) on the Connecting Module. First loosen the union nut and tighten again after connection.

  3. Attach the Connecting Line and the hoses in the corresponding Clip.

  4. Close the bracket of the Clip and fix it with the screw.

  5. Install the Cover over the connectors.