Target Angle Limits
With Target angle limits set, it is possible to monitor whether the nut is turned the desired angle during the tightening.
Parameter | Description | Default value |
|---|---|---|
Angle limits | Choose the section of the tightening, in degrees, in which to monitor the angle.
| Auto |
Angle min | Angle value for lower angle limit. | 0° |
Angle max | Angle value for upper angle limit. | 0° |
The parameter Measure angle at can have different values. The parameter is only available when angle monitoring is turned on for the tightening program used. By default the angle is measured at Max angle value. The possible values of the parameter are listed in the table below.
Name | Description |
|---|---|
Value at peak torque | Measures the angle at the highest torque value. |
Max angle value | Measures the highest angle during tightening. |