Target Angle Limits

With Target angle limits set, it is possible to monitor whether the nut is turned the desired angle during the tightening.

Parameter

Description

Default value

Angle limits

Choose the section of the tightening, in degrees, in which to monitor the angle.

  1. Auto: The angle monitoring limits are automatically calculated by the controller.

  2. Manual: The angle monitoring limits are manually entered.

Auto

Angle min

Angle value for lower angle limit.

Angle max

Angle value for upper angle limit.

The parameter Measure angle at can have different values. The parameter is only available when angle monitoring is turned on for the tightening program used. By default the angle is measured at Max angle value. The possible values of the parameter are listed in the table below.

Name

Description

Value at peak torque

Measures the angle at the highest torque value.

Max angle value

Measures the highest angle during tightening.