TensorPulse Loosening Parameters
Parameter name | Description | Default value |
---|---|---|
Loosening enabled | Off: Loosening is disabled. On: Loosening is enabled and additional parameters can be configured. | On |
Detection torque | Auto: The value is set based on the tool type and the tool capability. Manual:The value is set manually. | Auto |
Detection torque | The minimum torque required to begin performing a loosening operation and produce a loosening result. | 3.5 Nm |
Run-up torque | Auto: The value is set based on the tool type and the tool capability. Manual:The value is set manually. | Auto |
Run-up torque | When the torque falls below Run-up torque, the loosening is considered to be OK. ![]() Depending on variations in screw length, the system cannot determine when the screw has been run up completely. This is for the operator to decide. | 1.75 Nm |
Loosening speed | Loosening speed will be attained when Run-up torque is reached. Max: The value is set to maximum. Manual:The value is set manually. | Max |
Loosening speed | Visible if Loosening speed is set to Manual | 1 rpm |