NOK Results List

Error message

Description

GUI location

Drive error

Internal driver error or driver loss detected.

N/A

Rehit

Attempt to tighten an already tightened bolt.

Tightening parameters (Edit) > Rehit detection

Soft start torque above max

Soft start torque exceeded maximum level.

Tightening parameters (Edit) > (Step 1) Soft Start > Torque max

Selftap torque above max

Selftap torque exceeded maximum level.

Tightening parameters (Edit) > (Step 2) Selftap > Torque max

Selftap torque below min

Selftap torque below minimum limit.

Tightening parameters (Edit) > (Step 2) Selftap > Torque min

Safety torque limit low

Automatically calculated torque value to ensure torque sensor is mounted correctly.

N/A

Rundown torque above max

Rundown torque exceeded maximum level.

Tightening parameters (Edit) > (Step 2) Rundown torque limits > Torque max

Rundown angle above max

Rundown angle exceeded maximum level.

Tightening parameters (Edit) > (Step 2) Rundown angle limits > Angle max

Rundown exceeded max time limit

Rundown time exceeded maximum limit.

Tightening parameters (Edit) > (Step 2) Rundown angle limits > Time max

Rundown below min time limit

Rundown time below minimum limit.

Tightening parameters (Edit) > (Step 2) Rundown angle limits > Time min

Rundown torque below min

Rundown torque below minimum level.

Tightening parameters (Edit) > (Step 2) Rundown torque limits > Torque min

Rundown angle below min

Rundown angle below minimum level.

Tightening parameters (Edit) > (Step 2) Rundown angle limits > Angle min

Final step torque above max

Final step torque exceeded maximum level.

Tightening parameters (Edit) > (Step 3) Final step > Torque limits Manual > Torque max

Final step angle above max

Final step angle exceeded maximum level.

Tightening parameters (Edit) > (Step 3) Final step > Angle max

Final step torque below min

Final step torque below minimum level.

Tightening parameters (Edit) > (Step 3) Final step > Torque limits Manual > Torque min

Final step angle below min

Final step angle below minimum level.

Tightening parameters (Edit) > (Step 3) Final step > Angle max

Tightening timeout

Tightening time limit exceeded.

[Multistep] Tightening parameters (Edit) > Step dependent

[Other tightening programs]: fixed parameter set to 30 seconds

Trigger lost

Tool trigger was released before target was reached.

[Multistep]: trigger release before tightening step target has been reached

[Other tightening programs]: trigger release before tightening stage has finished

Slip off

Socket has slipped off the nut.

Tightening parameters (Edit) > (Step 3) Tightening parameters > Slipoff detection time

Target reached before final step

Target torque reached before final step in tightening program.

Target torque

Post view torque below min

Post view torque below minimum level.

Tightening parameters (Edit) > (Step 2) Post view torque > Torque min

Post view torque above max

Post view torque exceeded maximum level.

Tightening parameters (Edit) > (Step 2) Post view torque > Torque max

Post view torque interval not reached

Post view torque interval not reached.

Tightening parameters (Edit) > (Step 2) Post view torque > Torque min length

Torque compensation interval not reached

Torque compensation interval angle before rundown end not reached.

Tightening parameters (Edit) > (Step 3) Torque compensation > Torque compensation point

Tool movement exceeded

Tool was moved beyond set angle limits.

Tightening parameters (Edit) > (Step 1) TrueAngle compensation (On); Tool movement limits > Positive/Negative

Current monitoring error

Current monitoring error.

Tightening parameters (Edit) > (Step 1) Current monitoring (On)

Final step exceeded max time limit

[TurboTight] Tightening parameters (Edit) > (Step 3) Final step > Time max

Final step below min time limit

[TurboTight] Tightening parameters (Edit) > (Step 3) Final step > Time min

TurboTight time limit exceeded

TurboTight time limit exceeded.

[TurboTight] Tightening parameters (Edit) > (Step 3) Final step > Time max

Snug monitor high

Wrench only. Monitor detected snug value exceeded.

Tightening parameters (Edit) > Rundown stage (Step 2) Rundown complete > Rundown complete torque

No residual torque

Wrench only. Residual torque was under threshold.

[TurboTight] + [TensorPulse] Tightening parameters (Edit) > (Step 3) > Tightening parameters > Residual torque correlation factor

Overspeed

Wrench only. Wrench gyro failed to measure angle due to high speed.

N/A

Stopped

Stopped externally before target was reached.

[Multistep]: Stopped externally before tightening step target has been reached
[Other tightening programs]: Stopped externally before tightening stage has finished