Front End Configuration
Configure the tool to use the correct front end attachment.
Go to Tool in the home menu and select Cable Tool > Front End Configuration.
Select the Front End Type.
If Open End is selected, the following parameters can be set.
Before using the Gear Front Attachment (GFA) - whether Open End or Closed End - ensure that the tool head and tool body are properly assembled and configured. Failure to do so may result in damage to the mechanical stop in the head, especially for the Open End type, if the tool operates in the wrong direction.
Settings
Description
Reversed rotation direction
Indicates the rotation direction.
Yes: Reversed
No: Not reversed (Default)
Tightening direction
CW: Default
Tightening direction set to clockwise.
CCW
Tightening direction set to counterclockwise.
Positioning limit
Manual
Set the Torque positioning limit.
Auto: Default
Torque positioning limit automatically set to 2% of maximum torque but at least 2 Nm.
Select Apply to set up the configuration. The tool will restart.
Perform Open End tuning
The Open End tuning function is available for tools configured with Open End Gear Front Attachment (GFA). The function calculates the true gear ratio of both the tool and the extension combined, and saves it to the tool. The tuning will take approximately two minutes to perform.

When the Open End tuning is completed the tool must be calibrated with the Open End extension attached.
Select Perform and then press the trigger on the tool.
Follow the instructions on the screen and keep pressing the tool trigger until the Open End tuning is completed.
If the Open End tuning was successful an OK event will be displayed.
If the Open End tuning was not successful, or the tool trigger was released before the tuning was finished, an NOK event will be displayed.