Configuration of the Open End
Before using an open end tool, make sure that the tool head and tool body have been assembled and configured correctly. If not, the tool can run in the wrong direction and the mechanical stop in the open-end head may be damaged.
After performing a tightening with an open end tool, it is possible to let the open end tool getting to the opening position again through the open end configuration.
Configure the open end strategies and settings through the HMI (Human Machine Interface).
The open end configuration is applicable only to cable tools, IXB tools, and STB tools.
The open end configuration is not applicable to Flex and to synchronized tightening.
Open End Configuration
Settings | Description |
---|---|
Automatic Positioning | After performing a tightening with an open end tool, it is possible to let the open end tool getting to the opening position again automatically. A toggle key turns the Automatic Positioning On or Off:
Automatic Positioning is applicable only to Multistep tightening programs. Automatic Positioning is applicable only to cable tools and IXB tools. |
Positioning Strategy | Select the Positioning Strategy to let the open end tool getting back to the opening position after the tightening.
We recommend to use Reverse Torque Based and Forward Fast Start strategies for open end tools with swiveling front part. Reverse Torque Based and Forward Fast Start strategies are applicable only to cable tools and IXB tools. |
Positioning Speed | Positioning Speed defines how quickly the tool should get to the opening position. The operator can enter a Positioning Speed value which ranges from 5% through 100%. |