- Power Focus 6000
- Configuration
- Working with the Controller Tab
- Synchronized Tightening
- Synchronized Tightening Signals
- Output Signals
Output Signals
Search
Signal | Converter | Signal Type | Value Type | Size Min [bit] | Size Max [bit] | Devices |
---|---|---|---|---|---|---|
Bolt Tightening Status - 79 | Standard | State | uint32 array | 32 | 32 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Bolt Tightening Status - 79 | FordResultStatus | State | 4 | 4 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Bolt Tightening Status - 79 | CompactErrorStatus | State | 4 | 4 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Channel Hardware Status - 81 | State | uint32 array | 1 | 64 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Channel Tightening Status - 80 | Standard | State | uint32 array | 1 | 64 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Channel Tightening Status - 80 | FordResultStatus | State | 4 | 4 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Channel Tightening Status - 80 | CompactErrorStatus | State | 4 | 4 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Confirm loosening - 206 | Standard | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, Stacklight, TLS Tag, I/O Expander |
Confirm loosening - 206 | Invert | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, Stacklight, TLS Tag, I/O Expander |
Cycle Complete - 77 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Cycle Emergency stopped - 202 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Cycle NOK - 76 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Cycle OK - 75 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Cycle Ready To Start - 82 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Cycle Running - 78 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Data Drop Active - 199 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Data Hold Active - 198 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Fieldbus AsyncData From PF - 107 | State | uint8 array | 48 | 2048 | Fieldbus | |
Last Cycle No Result - 200 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
No System Error - 83 | Standard | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
No System Error - 83 | Invert | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
No System Warning - 102 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, Stacklight, TLS Tag, I/O Expander | |
Selected Mode Id - 72 | Standard | State | Integer | 1 | 32 | Fieldbus |
Selected Mode Id - 72 | TreatZeroAsOne | State | Integer | 1 | 32 | Fieldbus |
Sync Mode Valid - 207 | Standard | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Sync Mode Valid - 207 | Invert | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Test Bolt Activated - 91 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Tools in Zero Position - 210 | Event | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
ToolsNet Connection Lost - 133 | Standard | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, Stacklight, TLS Tag, I/O Expander |
ToolsNet Connection Lost - 133 | Invert | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, Stacklight, TLS Tag, I/O Expander |
ToolsTalk Connection Lost - 208 | Standard | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, ST Selector, Stacklight, TLS Tag, I/O Expander |
ToolsTalk Connection Lost - 208 | Invert | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Tool Functions, ST Selector, Stacklight, TLS Tag, I/O Expander |
Total Remaining Sequence Counter - 205 | State | Integer | 1 | 16 | Fieldbus, ST Selector | |
Total Sequence Counter - 204 | State | Integer | 1 | 16 | Fieldbus, ST Selector | |
Total Sequence Size - 203 | State | Integer | 1 | 16 | Fieldbus, ST Selector | |
Waiting To Continue - 201 | State | Boolean | 1 | 1 | Fieldbus, Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Showing 1 to 36 of 36 entries