Considerations during the use of Spindles

The list below states what to be considered when using spindles and StepSync or FlexSystem.

  • ILG will not receive the tc_results messages when StepSync and Open Protocol is being used. The ILG process will still work, however the HMI will not show torque and angle results.

  • It is recommended to use the same pset for all spindles.

    The following information applies if the spindles are using different psets:

    1. If the psets have mixed thread directions (clockwise/counterclockwise), ILG will not read the thread direction correctly in Sync Mode.

    2. If all psets have counterclockwise thread direction: No Mode shall have the same ID number as an existing Pset ID number.

      Alternatively, all Mode Ids should be larger than the largest Pset ID.

  • If the result of a spindle is NOK the position (and all visualized bolts) will be marked red.

  • Rework must be performed on all spindles, it is not possible to perform rework on individual spindles.