Output Message
Options nr 1-9 in the list below are the predefined output messages that can be chosen. To use other messages in ILG, select the Advanced option.
Type | Description |
|---|---|
Finish process | Ends the current workpiece gracefully, resulting in a process result message. Choose the affected workplace. |
Generic IO 1 to 10 | Set the state of one generic IO. Choose the tool, the relay ID and the state, which are to be used. |
Enable Bypass Tool Lock Mode | Activates the Bypass Tool Lock Mode. |
Disable Bypass Tool Lock Mode | Deactivates the Bypass Tool Lock Mode. |
Lock tool | Locks the tool by ILG (not by other sources). Choose a tool to match. |
Notify | Notifies the user. |
Release tool | Releases the tool by ILG (not by other sources). Choose a tool to match. |
Reset process | Resets the process. |
Start workpiece | Starts the workpiece. Choose a tool to match. |
Advanced | Is only for advanced users, who want to send another internal predefined output message in ILG. |