Output Message

Options nr 1-7 in the list below are the predefined output messages that can be chosen. To use other messages in ILG, select the Advanced option.

Type

Description

Finish process

Ends the current workpiece gracefully, resulting in a process result message. Choose the affected workplace.

Generic IO 1 to 10

Set the state of one generic IO. Choose the tool, the relay ID and the state, which are to be used.

Lock tool

Leaving a position triggers this option. Choose a tool and a position to match.

Notify

Triggers on locking the tool by ILG (not by other sources). Choose a tool to match.

Release tool

The workpiece is finished. Choose a workplace and a result to match.

Reset process

ILG received a VIN through Open Protocol. Choose a tool and a VIN to match.

Start workpiece

Triggers on releasing the tool by ILG (not by other sources). Choose a tool to match.

Advanced

Is only for advanced users, who want to react on some other internal predefined messages in ILG.