Final Target Torque - 31015

Gets the target torque of the tightening program for a performed tightening. The value is copied from the program of the tightening result and is published after the tightening.

The Multistep programs retrieve the Target Torque from the last tightening step in the tightening program defined as Step Category "Final".

Converter

Signal Type

Value Type

Size Min [bit]

Size Max [bit]

Standard

Event

Integer

32

32

FixedPointToDecimal

Event

Integer

32

32

Devices

  • Fieldbus: TRUE

  • Indicator Box: FALSE

  • Internal I/O: FALSE

  • Operator Panel: FALSE

  • Tool Functions: FALSE

  • ST Selector: FALSE

  • Stacklight: FALSE

  • TLS Tag: FALSE

  • I/O Expander: FALSE

To avoid duplicating signals, it is possible to define Value Converters.