Master Unlock - 10005

Master Unlock is an input signal which unlocks the following functions and signals.

FUNCTIONS:

  • Disable loosening at OK tightening

  • Disable loosening at NOK tightening

  • Disable tightening

  • Max consecutive NOK

  • Tool Lock on Sequence complete

SIGNALS:

  • 20001 - Pending Event Acknowledge Lock

  • 20002 - Lock Tightening

  • 20003 - Lock Loosening

  • 20004 - Lock Tool Active High

  • 20013 - WorkTask Lock Tightening

  • 20014 - WorkTask Lock Loosening

  • 20015 - Batch Done lLock

  • 20018 - Open Protocol Lock

  • 20020 - Fieldbus Lock Tightening

  • 20021 - Fieldbus Lock Loosening

  • 20022 - Disable Loosening At OK Tight

  • 20023 - Too Many NOK Tightenings Lock

  • 20033 - Line Control Lock

  • 20034 - Locked By Alternative Identifier

Name in SoftPLC: MASTER_UNLOCK

Signal Type

Value Type

Size Min [bit]

Size Max [bit]

Event

Boolean

1

1

Devices