EHMI Start-up Progress Indications

The information in this section is only valid for tools running IxB Software from version 3.7 and onwards.

When starting the tool, the EHMI will indicate if a software update is in progress by displaying the following messages:

  • Check for software update

  • Updating <module> App/Boot

  • Starting controller

NOTICE

Do NOT pull the battery from the tool during the software update procedure. The tool can get damaged.

A module is a subsystem or component which is part of the IxB tool, and updated through the IxB Software.

Module (as shown on the display)

Description

MRT

Main board

MCB

Power module

FTS

Front transducer

EHMI

Extended HMI

BHMI

Basic HMI

If an error occurs during the software update, the following message will be displayed:

  • Software update failed (errorId)

The errorId corresponds to error messages, as follows:

Id

Error Message

Description

Suggested Action

0

None

-

-

1

Module board info not valid

Module produced with incorrect data

Replace module

2

Module device information not valid

Module produced with incorrect data

Replace module

3

Module file corrupt

File system is corrupt

Replace IAM

4

Module firmware not compatible with hardware

Software not compatible with hardware

Update to later release

5

Module firmware file not found

File system is corrupt

Replace IAM

6

Error when reading module firmware file

File system is corrupt

Replace IAM

7

Communication timeout when trying to update module

Damage on the connector/cable or the module

Replace IAM

8

Error when receiving data from module

Damage on the connector/cable or the module

Service the tool

9

Unexpected reply from module

Damage on the connector/cable or the module

Service the tool

10

Module unreachable

Damage on the connector/cable or the module

Service the tool

11

Error when transmitting data to module

Damage on the connector/cable or the module

Service the tool

12

System on backup battery

System is running on backup battery

Restart tool - do not remove battery or power adapter until update is complete