Updating the communication channel

  1. Access the MWR-KIT web GUI.

  2. From the main menu on the left side of the MWR-KIT page, select Scan.

  3. In the Scan section of the Wrench scan page, select the checkbox of the region where to scan the available wrenches.

    Then, click on the Start Scan button.

    In the upper-left part of the MWR-KIT page, the status changes from the Active mode to the Configuration mode and the progress of the Scanning process is displayed in percentage.

    The MWR detected during the Scanning process are displayed in the Tools section of the Wrench scan page.

  4. In the Tools section, select the MWR to update with the new channel.

    Then, click on the Configure button.

  5. In the Remote configuration section, select a channel from the Channel drop down list.

  6. In the Remote configuration section, select/deselect the Save local config checkbox to enable/disable the saving of the MWR communication channel on the MWR-KIT

    If the Save local config checkbox is not selected, the channel is set but not stored.

    Then click on the Update button.