Error Codes
Error format: E<Error Group>-<ErrorCode>
Error code is for internal use only.
If the error is not solved, contact Atlas Copco representative.
Error Group  | Error Category  | Service Hints  | 
|---|---|---|
none  | item  | none  | 
00  | Error updating tool SW  | SW update issue. Try to connect tool to TTS2. It may give more info.  | 
01  | General SW error  | General software issue. Update to latest software.  | 
02  | General SW error  | General software issue. Update to latest software.  | 
03  | Front light error  | Front light issue. Check cable and/or replace board.  | 
04  | Tool HMI error  | Tool HMI error. 1. Update software using FFU flag. 2. Check cable.  | 
05  | General SW error  | Motor control issue. 1. Check Main board (MB) - Motor control board (MCB) connection. 2. Update to latest software.  | 
06  | Tool memory error  | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters.  | 
07  | Motortune error  | Motor tune issue. 1. Update software to latest. 2. Try running tests in TTS2. 3. Check that the commutation board in the back of the tool is mounted correctly. A possible problem is that it isn't pushed properly into place.  | 
08  | General SW error  | Parameter issue. Try connecting tool to TTS2 to reset factory parameters.  | 
09  | General SW error  | Radio issue. 1. Check cable. 2. Check tool antennae cable. 3. Update software with FFU-flag.  | 
10  | Error updating radio SW  | Radio SW update issue. 1. Check cable. 2. Check tool antennae cable. 3. Update software with FFU-flag.  | 
11  | General SW error  | Radio issue. 1. Check cable. 2. Check tool antennae cable. 3. Update software with FFU-flag.  | 
12  | General SW error  | Radio Bluetooth issue. 1. Check cable to radio module. 2. Update software with FFU-flag.  | 
13  | General SW error  | Radio WIFI issue. 1. Check cable for radio module. 2. Update software with FFU-flag.  | 
14  | General SW error  | Smart web-configuration issue. 1. Check cable for radio module. 2. Update software with FFU-flag.  | 
15  | RBU HW error  | IAM issue. Try resetting SD-card checksums in TTS2.  | 
16  | RBU HW error  | IAM issue. Try resetting SD-card checksums in TTS2.  | 
17  | General SW error  | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters.  | 
18  | General HW error  | Indicator board issue.  | 
19  | General SW error  | General software issue. Update to latest software.  | 
20  | General SW error  | Internal communication issue. Check Main board - Motor control board connection.  | 
21  | General SW error  | Internal communication issue. Check Main board - Motor control board connection.  | 
22  | General SW error  | General software issue. Update to latest software.  | 
23  | Backup battery error  | Backup battery issue. Check backup battery connection.  | 
24  | General SW error  | General software issue. Update to latest software.  | 
25  | Error updating motor control board  | Motor control board (MCB) software update issue. 1. Check MCB connection. 2. Update to latest software.  | 
26  | General SW error  | Motor control board communication error. 1. Check MCB connection. 2. Update to latest software.  | 
27  | General SW error  | General hardware or software issue.  | 
28  | Power supply error  | General power supply issue.  | 
29  | General SW error  | Tool device identification issue. Connect to TTS2, may help to re-write tool identity.  | 
30  | General SW error  | Tool device identification issue. Connect to TTS2, may help to re-write tool identity.  | 
31  | General SW error  | Torque transducer issue. Check torque transducer and cable.  | 
32  | General tightening error  | General tightening error.  | 
33  | Tool trigger error  | Tool trigger issue. 1. Test trigger in TTS2. 2. Check that trigger is not broken. 3. Replace main board.  | 
34  | General SW error  | Tightening trace issue.  | 
35  | General SW error  | Tightening trace issue.  | 
36  | General HW error  | Problem with hardware or connection between MB/MCB boards. 1. Check mechanical connection. 2. Replace MCB and/or MCB.  | 
37  | Function button error  | Problem with changing tool direction. 1. Test function button in TTS2. 2. Update SW to latest version.  | 
38  | General HW error  | Torque transducer issue. Check torque transducer and cable.  | 
39  | General HW error  | General HW issue.  | 
40  | General HW error  | General HW issue. Try replacing MB.  | 
41  | Error updating tool SW  | SW update issue. Try to connect tool to TTS2, it may give more info.  | 
42  | Error updating tool SW  | SW update issue. Try to connect tool to TTS2, it may give more info.  | 
43  | General HW error  | Indicator board issue. <SRB HA does not use the indicator board>  | 
44  | General HW error  | Second trigger issue. 1. Check cable and second trigger board. 2. Disconnect Gear ID board from front light board. 3. Replace front light board.  | 
45  | Error reading SRB HA tool config  | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters.  | 
46  | General SW error  | SRB HA - Smart result issue. 1. Try removing "RESULT.CSV" from IAM in folder HA. 2. Update software.  | 
47  | General SW error  | SRB HA - Smart program issue. 1. Update to latest tool software. 2. Restore factory settings in TTS2.  | 
48  | General SW error  | SRB HA - Smart program or Set&Go issue. 1. Update to latest tool software. 2. Restore factory settings in TTS2.  | 
49  | General SW error  | General software issue. Update to latest software.  | 
50  | General HW error  | IAM SD-card issue.  | 
51  | General SW error  | General software issue. Update to latest software.  | 
52  | General SW error  | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters.  | 
53  | Open end configuration error  | Open end configuration issue. <SRB HA does not support this feature>  | 
54  | General SW error  | General HW issue.  | 
55  | Front light HW error  | Front light issue. 1. Check cable and/or replace board. 2. Update to latest software.  | 
56  | Push button error  | Function button error. Runt function button test in TTS2. Replace button board or cable.  | 
57  | General SW error  | HW input error. Try replacing Main board.  | 
58  | General SW error  | HW input error. Try replacing Main board.  | 
59  | General SW error  | Problems settings up Radio module in Access point mode.  | 
60  | Error updating indicator board SW  | Indicator board issue. <SRB HA does not use the indicator board>  | 
61  | General SW error  | Front light communication issue. Check cable and front light board.  | 
62  | RBU HW error  | IAM SD-card issue.  | 
63  | General HW error  | Main board FPGA error. 1. Try updating with latest software. 2. Replace main board.  | 
64  | General HW error  | Main board FPGA update issue. 1. Try updating with latest software with FFU flag. 2. Replace main board.  | 
65  | General HW error  | Parameter memory issue. Try connecting tool to TTS2 to reset factory parameters.  | 
66  | General SW error  | Internal communication issue. Related to Radio or TTS2 communication.  | 
67  | General SW error  | Internal communication issue. Related to Radio or TTS2 communication.  | 
68  | General SW error  | Internal communication issue. Related to Radio or TTS2 communication.  | 
69  | General SW error  | General SW issue.  | 
70  | General SW error  | General SW/HW issue.  | 
71  | General SW error  | General SW/HW issue.  | 
72  | General SW error  | General SW issue.  | 
73  | Software update error  | General SW update issue.  | 
74  | FH_ECG_ToolsTalkServices2Test  | Issue with TTS2 enabled tests.  |