LED Indicators

Autonomous Status Indicators:

Indication

Flash pattern

Battery status

Remark

No indication

Good

Battery is healthy and performing well

Steady yellow light for 1.5 second

Self-test when powering on

Battery operational after 1.5 second

Steady yellow light

Battery cell temperature out of range:
Too high temperature

Let battery cool before continuing operation

Battery cell temperature out of range:
Too low temperature

Make sure ambient temperature is within range
See Ambient Temperature

Too high discharge current to tool

Check the tool configuration
Remove battery from tool

Too high charge current

Remove battery from charger and replace charger

Invalid charger

Use appropriate charger
See Battery Charger Data in Safety Information found on ServAid

Too high voltage applied externally to battery connector

Use appropriate charger
See Battery Charger Data in Safety Information found on ServAid

Steady red light

Unrecoverable error

Replace battery

State of Charge (SOC) Indicators:

Press release button (1) to show SOC indication (2).

Indication

Battery charge

Remark

Full charge

Medium charge

Charge battery when possible

Low charge

Charge battery

Empty

Charge battery

When attaching the battery to the charger, the charging procedure will start and go on for 20 seconds. The charging is then temporarily stopped as the battery performs a self-test. The self-test continues for 10 seconds and after this the battery resumes charging again.

State of Health (SOH) Indicators:

SOH indicates how much of the original capacity that is left in the battery cells, that is, how much the battery has degraded since it was new.

SOH is not an indication of current battery charge.

When the button is pressed for 10 seconds the battery SOH is shown, as listed below:

Indication

Flash pattern

State of Health (SOH)

1 flash, green

More than 80% of the original capacity

1 flash, yellow

Between 70-80% of the original capacity

1 flash, red

Less than 70% of original capacity

Manual Status Indicators:

When the release button is pressed for 20 seconds the current battery state is shown by the LEDs in position 3 flashing in sequence, as listed below.

Battery 14V (4211613002) with generation letter A and B is not equipped with a green LED. The green LED is instead indicated with red light, as described in Battery 14V LED Behavior.

LED Sequence

Battery State

Green, green, green

Sleep, normal state

Green, green, yellow

Idle, normal state

Green, green, red

Empty, normal state

Green, green, white

Charge over temperature, transient state

Green, yellow, green

Charge under temperature, transient state

Green, yellow, yellow

Discharge over temperature

Green, yellow, red

Discharge under temperature

Green, yellow, white

Charge over current

Green, red, green

Discharge over current

Green, red, yellow

MOSFET over temperature

Green, red, red

No parameters

Green, red, white

Calibration mode

Green, white, green

Fully charged state

Green, white, yellow

Discharging

Green, white, red

Charging

Yellow, green, green

Transport mode

Yellow, green, yellow

Powering down

Yellow, green, red

Cell temperature sensor broken

Yellow, green, white

MOSFET temperature sensor broken

Yellow, yellow, green

Cell voltage too low

Yellow, yellow, yellow

Cell voltage too high

Yellow, yellow, red

Cells are unbalanced

Yellow, yellow, white

Pack is over voltage

Yellow, red, green

Charge MOSFET is broken

Yellow, red, yellow

Discharge MOSFET is broken

Yellow, red, red

Initializing at startup

Yellow, red, white

Discharge off, test mode

Yellow, white, green

Charge off, test mode

Yellow, white, yellow

Discharge and charge off, test mode

Yellow, white, red

Disconnect from charger state

Yellow, white, white

Charger is invalid

Red, green, green

Charge software is wrong version

Red, green, yellow

Charge FET self-test

Red, green, red

Discharge FET self-test

Red, green, white

Sum of cell voltages not accurate

Red, yellow, green

Faulty cell connector

Red, yellow, yellow

Accumulator over voltage

Red, yellow, red

Mismatch between temperatures

Red, yellow, white

Pack over temperature

Red, red, green

Over charged

White, white, red

Pack is dead

Battery Power-off

If the release button is pressed for more than 60 seconds, all three white SOC indicators (2) will flash one by one, in sequence. After 30 seconds of indicators flashing the battery will power-off.