- Power Focus 6000
- Reference
- Input Signals
Input Signals
Search
Signal | Converter | Signal Type | Value Type | Size Min [bit] | Size Max [bit] | Devices |
---|---|---|---|---|---|---|
Abort Sequence - 10012 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Abort Sequence and Clear Results - 10127 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Acknowledge Events - 10004 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Activate Tool Scanner - 10075 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Batch Decrement - 10002 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Batch Increment - 10001 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Bypass Identifier - 10123 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Bypass Tightening Program - 10008 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Disable Fieldbus - 10049 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Disable tool - 30000 | Standard | State | Boolean | 1 | 1 | Fieldbus |
Disable tool - 30000 | Invert | State | Boolean | 1 | 1 | Fieldbus |
Disable Tool Scanner - 10119 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, TLS Tag, I/O Expander | |
Dynamic Batch Size - 10074 | State | Integer | 1 | 16 | Fieldbus | |
External OK - 10063 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Fieldbus Lock Loosening - 20021 | Standard | State | Boolean | 1 | 1 | Fieldbus |
Fieldbus Lock Loosening - 20021 | Invert | State | Boolean | 1 | 1 | Fieldbus |
Fieldbus Lock Tightening - 20020 | Standard | State | Boolean | 1 | 1 | Fieldbus |
Fieldbus Lock Tightening - 20020 | Invert | State | Boolean | 1 | 1 | Fieldbus |
Flush Read Result Queue - 30005 | Event | Boolean | 1 | 1 | Fieldbus | |
ID for Dynamic Batch Size - 10073 | Standard | State | Integer | 1 | 16 | Fieldbus |
ID for Dynamic Batch Size - 10073 | TreatZeroAsOne | State | Integer | 1 | 16 | Fieldbus |
Lock Loosening - 20003 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Lock Tightening - 20002 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Lock Tool Active High - 20004 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Lock Tool Active Low - 20061 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Manual Mode - 10061 | Standard | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Manual Mode - 10061 | Invert | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander |
Master Unlock - 10005 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Pulse Stop - 10030 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Read Result Handshake Ack - 30004 | State | Boolean | 1 | 1 | Fieldbus | |
Reset All Identifiers - 10115 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Reset Batch - 10003 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Reset Batch Sequence - 10053 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Reset Bistable Relay - 10022 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Reset Latest Identifier - 10114 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Reset Relays - 10120 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, I/O Expander | |
Reset Sequence Status - 10118 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Reset Too Many NOK - 10013 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input - 10020 | Standard | State | Integer | 1 | 16 | Fieldbus, ST Selector |
Select Input - 10020 | TreatZeroAsOne | State | Integer | 1 | 1 | Fieldbus, ST Selector |
Select Input and Dynamic Batch Size - 30007 | Standard | State | Integer | 16 | 16 | Fieldbus |
Select Input and Dynamic Batch Size - 30007 | TreatZeroAsOne | State | Integer | 16 | 16 | Fieldbus |
Select Input Bit 0 - 10016 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 1 - 10017 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 2 - 10018 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 3 - 10019 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 4 - 10066 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Select Input Bit 5 - 10067 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Select Input Bit 6 - 10068 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 7 - 10069 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 8 - 10070 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Input Bit 9 - 10071 | State | Boolean | 1 | 1 | Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Select Loosening - 10029 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Select Next Identifier Number - 10116 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, ST Selector, Stacklight, I/O Expander | |
Select Previous Identifier Number - 10117 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, ST Selector, Stacklight, I/O Expander | |
Set Bistable Relay - 10021 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Set CCW Direction - 10132 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Set Zero Position - 10135 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Socket Selector External Green Light - 10046 | Standard | State | uint64 | 1 | 64 | Fieldbus |
Socket Selector External Green Light - 10046 | SocketLedControlTwoDevices | State | uint64 | 1 | 64 | Fieldbus |
Socket Selector External Red Light - 10047 | Standard | State | uint64 | 1 | 64 | Fieldbus |
Socket Selector External Red Light - 10047 | SocketLedControlTwoDevices | State | uint64 | 1 | 64 | Fieldbus |
Start Loosening - 10011 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Start Tightening - 10010 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Start Tightening Pulse - 10024 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Start Tools - 10028 | State | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Stop (pulse) - 10129 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
To SoftPLC - 10065 | State | uint8 array | 1 | 1 | Indicator Box, Internal I/O, Operator Panel, Stacklight, I/O Expander | |
Toggle CW/CCW - 10130 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Toggle CW/CCW For Next Run - 10131 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Unlock Tool on Complete - 10051 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander | |
Unlock Tool on Disable - 10059 | Event | Boolean | 1 | 1 | Fieldbus, Internal I/O, Operator Panel, Tool Functions, Stacklight, I/O Expander |
Showing 1 to 72 of 72 entries