Product data

  • Operating torque measuring range: 10 [N·m] - 50 [N·m] / 7.4 [lb·ft] - 36.9 [lb·ft]

  • Drive: 9x12 mm.

  • Overall length: 234 mm.

  • Operating torque range: from 20% to 100% of the capacity

  • Torque measurement accuracy (within the operating torque range): 2%

  • Mechanical repeatability click: ± 4%

  • Overload capacity: 120 % of nominal capacity

  • Maximum angular speed: 250 °/s

  • Angle measurement accuracy: ± 3.6 ° / 360 ° (at 6 ° per second)

  • Temperature stability of torque measurement: +10 °C to +40 °C (10 °F to 104 °F)

  • Tightening results memory capacity: 8100 Data sets (maximum)

  • MWR-50 TA Reference Firmware version: 3.0.0