Lubrication

The tool is fitted with an angle gear which is lubricated with a fluid grease to ensure good wear resistance. To avoid overfilling, which could result in a rise in temperature and damage to seals, there is no lubrication nipple. Change the grease after approximately 200 running hours by removing the angle-gear spindle.

For accurate lubrication propertiets use Rhenus LKR03 fluid grease. The requisite amount of grease is max. 6 cm3.

Do not use ball bearing grease or chassis grease.