Application settings parameters

  • Application version: current version of the application.

General parameters

  • Background picture: click on the Add icon () to upload a new picture, or click on the Delete icon () to restore the default Atlas Copco background picture.

  • Date format: from the drop-down list, select the date format to use in the application.

  • Language: from the drop-down list select the language of the application.

  • Report format: from the drop-down list, select between DOCX and PDF.

  • Report logo: click on the Add icon () to upload a new picture and customize the logo displayed in the reports, or click on the Delete icon () to restore the default Atlas Copco logo.

  • Online interval check: from the drop-down list, select between 30 s or 60 s.

  • Torque measurement unit: from the drop-down list, select the measurement unit to use in the application.

  • Status for replaced tool: from the drop-down list, select the default status for the tool to replace in a tool swap operation.

  • OP devices: retrieve old results: by default enabled; when an Open Protocol measuring device is connected for the first time, all the results stored in the device are transferred to QA Supervisor.
    Once the measuring device is connected, this setting cannot be changed for the single device: if the switch is enabled, the old results are always retrieved; if the switch is disabled, the old results can no longer be retrieved.

If this option is disabled, at least one measurement must be stored in the device before connecting it to QA Supervisor.

If the new measuring device is created manually, it is possible to override this setting during the configuration of the Measuring Device parameters.

Deleted measurements

In the Deleted measurements section, select the Deleted measurements options to display the deleted results of the tests made by STbench/ STpad/STpalm.
Click on the switches to enable/disable the following options:

  • Display in pages and export: by enabling this option, it is possible to display the deleted results in the Data details card and in the exported excel files.

  • Display in reports: by enabling this option, it is possible to display the deleted measurements in the tests reports.

Not detected measurements

In the Not detected measurements section, select the Not detected measurements options to display the measurements not detected by STbench/STpad/STpalm.
Click on the switches to enable/disable the following options:

  • Display in pages and export: by enabling this option, it is possible to display the not detected measurements in the Data details card and in the exported excel files.

  • Display in reports: by enabling this option, it is possible to display the not detected measurements in the tests reports.

Traces

  • Display traces in application: by enabling this option, the Traces menu and the traces linked to the joints are displayed in the application.

Custom URLS

In the Custom URLS section, it is possible to add up to four URLS that will be available for navigation on STbench/ STpad/STpalm.
For each URL, type the name of the label. The labels will be displayed on STbench/ STpad/STpalm.

The web browser navigation bar will not be present on the devices: navigation is limited to the configured URLs and some basic browser functionality are inhibited (such as: next, back, refresh, right-click, etc.).

Due to screen size, QA Supervisor is not available for navigation on STpalm.

Additional status (for not in use tools)

In the Additional status (for not in use tools) section, define the condition of the tools that are not in use.
Assign a customized name to each status by typing the name in the Status text box.
Then, enable/disable one or more statuses by clicking on the status switch.

Status text boxes must always have a name.
The maximum number of characters for the Status name is 50.
It is not allowed to configure two statuses with the same name.

API communication

API are a set of commands that allow to integrate QA Supervisor with other systems.

In the API communication section, click on the switch to enable/disable API communication.
By default, the API enable switch is disabled.

Default values

In the Common section of the Default values, configure the parameters common to all inspections.
In the Default values section, configure the default values for Tool check, Joint check, Visual check, and Dimension inspections.

For the SPC inspections of each type, it is possible to enable a custom set of rules to be used by STpad.
In the Default value, click the value of the Enabled rules.
In the SPC Enabled rules page, enable or disable the rules to use and click Apply.