Transducer parameters
Name (*): type the name of the transducer.
Description: type a description of the transducer.
Model (*): add/select the transducer model.
Do one of the following:
Click Add icon (
) to add a new transducer model. In the Add Transducer Model dialog box, enter the details related to new transducer.
Then, click Save.
Click Search icon (
) to select a transducer model already configured.In the Transducer Model workspace, select the necessary transducer model.
Then, click Apply.
Serial number (*): type the serial number of the transducer.
Identifier: type the identification code linked to the transducer.
Location (*): select the area of the plant where using the new transducer model. By default it is set to the is the location of the user.
Do as follows:
Click Location icon (
).In the Location dialog box, select the area of the plant where using the new transducer model.
Then, click Apply.
Status (*): select one of the following options, depending on the status of the transducer:
In use: the transducer is ready to work on the production applications.
Service/Repair: the transducer cannot be used on the assembly line before maintenance is complete. The capability of the transducer is verified according to customer’s procedures.
Scrapped/Disabled: the transducer is out of order. Do not use it on the assembly line.
By default, the status is set to In use.
Sensitivity: type the sensitivity of the transducer.
Measurement unit: select the measurement unit to define the torque parameters of the transducer. The default measurement unit is defined both in the Application settings and in the Personal settings.
Min load: type the minimum load of the transducer.
Full scale: type the full scale of the transducer.
Supplier: click the arrow to open the supplier list and select the necessary supplier.
To add a new supplier, click Add icon (
).In the Add Supplier dialog box, enter the details related to new supplier.
Then, click Save.
Purchase date: click the box and select the purchase date.
To delete a purchase date previously configured, click Delete icon (
).Calibration certificates: in the Calibration certificates box, select the necessary calibration certificate.
To add a new calibration certificate, click Add icon (
).In the Add Calibration Certificate dialog box, enter the following details related to new calibration certificate:
Calibration procedure (*): type the name of the Calibration procedure used to calibrate the transducer.
Calibration system: calibration system of the current calibration certificate. It is the traceability information for the selected transducer with a known accuracy, higher than the expected device under calibration and certificated according the same standard for which the calibration certification is claimed for the device under test.
Calibration system S/N: type the serial number of the system used to calibrate the transducer.
Reference transducer: traceability information for the transducer device used to calibrate a measuring device under test, where the sensitivity and the precision is proved and certified so that its output can be used as reference values for the comparisons in the calibration procedure.
Reference transducer S/N: type the serial number of the reference transducer used.
Certificate number: type the number of the calibration certificate.
Certificate link (attachment): attachment box for any document related to the calibration certificate.
Certificate date: enter the date of the emission of the certificate.
Certification expiry date (*): enter the expiry date of the calibration certificate.
Laboratory: name of the laboratory where the calibration certificate was done.
Laboratory accreditation ID: type the accreditation identification number of the laboratory where the calibration certificate was done.
Accreditation body: type the name of the accreditation body. The Accreditation body is the independent body that assessed the laboratory for the conformity to the reference standard.
Then, click Save.
To edit a calibration certificate already configured, in the Calibration certificates box, select it.
Click Edit icon (
).In the Edit Calibration Certificate dialog box, edit the calibration certificate.
Then, click Save.
To delete a calibration certificate already configured, in the Calibration certificates box, select it.
Then, click Delete icon (
).Measuring devices: in the Measuring devices box, select the necessary measuring device.
To add a new measuring device, click Add icon (
).In the Add Measuring Device dialog box, enter the details related to new measuring device.
To select a measuring device already configured, click Search icon (
).Then, click Save.
In the Measuring devices workspace, select the necessary measuring device.
Then, click Apply.
To delete a measuring device already configured, in the Measuring devices box, select it.
Then, click Delete icon (
).Notes: if necessary, type a note.
Items marked with an asterisk (*) are required.