Impulse Single-Step Tightening Stage Parameters
Parameter name | Condition | Description | Default value |
---|---|---|---|
Pulse Energy | The Pulse energy delivered in the action pulse expressed in a percentage of the maximum energy the tool can deliver in each pulse. | 100% | |
Residual torque correlation factor | The term Residual torque correlation factor is similar to a calibration and adjusts between the dynamic torque, measured in the electrical tool, and the residual torque, measured by a control tool. | 100% | |
Premature torque loss detection time | A constant increase in torque is assumed when moving from rundown to tightening. A socket slip of, or a broken screw head can cause the torque decrease. This may be detected in a monitoring window. | 200 ms | |
Target torque | Final target torque for the tightening. | 0 Nm | |
Torque limits | Selected by radio buttons. Limits can be Automatically or Manually selected | Manually | |
Torque min | Torque limits = manual | Minimum torque for the step. | 0 Nm |
Torque max | Torque limits = manual | Maximum torque for the step. | 1 Nm |
Angle limits | Off:Angle limits is turned off. From Rundown complete: Angle limits is turned On. The system starts to monitor the tightening angle as soon as Rundown complete is reached and reports if angle limits are violated. From torque: Rundown angle limits is turned On. The system starts to monitor the tightening angle from the specified torque value and reports if angle limits are violated. | Off | |
Final angle monitoring torque | Torque value from where Angle limits monitoring starts. | 20 Nm | |
Angle min | Angle value for lower angle limit from the starting point. | 0° | |
Angle max | Angle value for the upper angle limit from starting point. | 0° | |
Time limits | Selected from a shortcut menu: Off:Time limits is turned off. From rundown complete: Time limits is turned On. The system starts to monitor the time as soon as rundown complete is reached and reports if the time limits are violated. From torque: Time limits is turned On. The system starts to monitor the time from the specified torque value and reports if the time limits are violated. | Off | |
Time monitoring torque | Time limits = from torque | Torque value from where the Time limits monitor starts. | |
Time min | Time limits = On | Minimum allowed time for tightening. | 10ms |
Time max | Time limits = On | Maximum allowed time for tightening. | 1000ms |
Pulse limits | Selected from a shortcut menu: Off: No pulse limit monitoring. From rundown complete: The monitoring starts when the Rundown complete torque is reached and reports if the number of pulses is outside the limit. From torque: The monitoring starts when the specific torque value is reached and reports if the number of pulses is outside the limit. | Off | |
Final pulse monitoring torque | Pulse limits = from torque | Torque value from when the pulse limits are monitored. | 18.75 Nm |
Pulses min | Pulse limits = on | Minimum number of pulses to reach the final target. | 2 |
Pulses max | Pulse limits = on | Maximum number of pulses to reach the final target. | 50 |