Test conditions

Temperature pulse unit: approx. 20° C.

Air pressure: 6,3 bar (90psi) dynamic

Hose size: 8 mm Hose length: 3 m

The tool should achieve the following values after maintenance:

Model

Free speed (r.p.m)

Pulse frequency (Hz)

Max Torque (minimum)(Nm)

EP 4 PTX SR42 - AT

4000 - 10%/+ 25%

22 - 26

13